Checking unit status and i/o activity, Figure 4–4 unit status on the cache display, Table 4–8 unit status columns (continued) – HP Array Controller HSG V8.7 Software User Manual

Page 183: Checking unit status and i/o activity –29, Unit status on the cache display –29, Unit status columns –29

Advertising
background image

Troubleshooting

4–29

Checking Unit Status and I/O Activity

Use the cache display to see the status and I/O activity for the logical
units configured on the controller (see Figure 4–4). Table 4–8 lists the
heading and contents for each column of the device status region.

Figure 4–4 Unit Status on the Cache Display

VTDPY> DISPLAY CACHE

S/N: ZG64100176 SW: v7.0 HW: CX-02

66% I/D

Hit 99.8% Idle

0 KB/S 0 Rq/S

Up: 0 5:16.42

Unit

ASWC

KB/S

Rd%

Wr%

Cm%

HT%

PH%

MS%

Purge BlChd BlHit

P0300

o

0

0

0

0

0

0

0

0

0

0

D0303

o^ b

0

0

0

0

0

0

0

0

0

0

D0304

0

0

0

0

0

0

0

0

0

0

P0400

0

0

0

0

0

0

0

0

0

0

P0401

0

0

0

0

0

0

0

0

0

0

D0402

x^ b

0

0

0

0

0

0

0

0

0

0

Table 4–8 Unit Status Columns

Column

Contents

Unit

Kind of unit (and its unit number):

D = disk drive or CD-ROM drive

P = passthrough device

? = unknown device type

A

Availability of the unit:

a = available to other controller

d = disabled for servicing, offline

e = mounted for exclusive access by a user

f = media format error

i

= inoperative

m = maintenance mode for diagnostic purposes

o = online. Host may access this unit through “this

controller.”

r = rundown with the SET NORUN command

v = no volume mounted due to lack of media

Advertising