03F20064

The SWAP interrupts have been cleared and re-enabled for all device
ports. Note that in this instance the Associated Port, Associated Target,
Associated Additional Sense Code, and Associated Additional Sense
Code Qualifier fields are undefined.

41

03F30064

An asynchronous SWAP interrupt was detected by the controller for the
device port indicated by the Associated Port field. Possible reasons for
this occurrence include:

n

device insertion or removal

n

shelf power failure

n

SWAP interrupts reenabled

Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.

41

03F40064

Device services had to reset the port to clear a bad condition. Note that
in this instance the Associated Target, Associated Additional Sense
Code, and Associated Additional Sense Code Qualifier fields are
undefined.

41

03F60402

The controller shelf is reporting a problem. This could mean one or both
of the following:

n

If the shelf is using dual power supplies, one power supply has
failed.

n

One of the shelf cooling fans has failed.

Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.

41

03F70401

The shelf indicated by the Associated Port field is reporting a problem.
This could mean one or both of the following:

n

If the shelf is using dual power supplies, one power supply has
failed.

n

One of the shelf cooling fans has failed.

Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.

41

03F80701

The EMU has detected one or more bad power supplies. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

03F90601

The EMU has detected one or more bad fans. Note that in this instance
the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.

41

Table D–1

Instance Codes (Continued)

Instance

Code

Description

Template