Event Reporting: Templates and Codes

D–21

02492401

The write cache module which is the mirror for the primary cache is
unexpectedly not present (missing). A cache is expected to be
configured and it may contain dirty write cached data. Note that in this
instance, the Memory Address, Byte Count, FX Chip register, Memory
Controller register, and Diagnostic register fields are undefined.

14

024A2401

Mirroring is enabled and the primary write cache module is expectedly
not present (missing). A cache is expected to be configured and it may
contain dirty write cached data. Note that in this instance, the Memory
Address, Byte Count, FX Chip register, Memory Controller register, and
Diagnostic register fields are undefined.

14

024B2401

Write-back caching has been disabled either due to a cache or battery-
related problem. The exact nature of the problem is reported by other
instance codes. Note that in this instance the Memory Address, Byte
Count, FX Chip register, Memory Controller register, and Diagnostic
register fields are undefined.

14

024F2401

This cache module is populated with DIMMs incorrectly. Cache
metadata resident in the cache module indicates that unflushed write
cache data exists for a cache size different than what is found present.
Note that in this instance the Memory Address, Byte Count, FX Chip
register, Memory Controller register, and Diagnostic register fields are
undefined.

14

0251000A

This command failed because the target unit is not online to the
controller. The Information field of the Device Sense Data contains the
block number of the first block in error.

51

0252000A

The last block of data returned contains a forced error. A forced error
occurs when a disk block is successfully reassigned, but the data in that
block is lost. Re-writing the disk block will clear the forced error
condition. The Information field of the Device Sense Data contains the
block number of the first block in error.

51

0253000A

The data supplied from the host for a data compare operation differs
from the data on the disk in the specified block. The Information field of
the Device Sense Data contains the block number of the first block in
error.

51

0254000A

The command failed due to a host data transfer failure. The Information
field of the Device Sense Data contains the block number of the first
block in error.

51

0255000A

The controller was unable to successfully transfer data to target unit. The
Information field of the Device Sense Data contains the block number of
the first block in error.

51

Table D–1

Instance Codes (Continued)

Instance

Code

Description

Template