23

SYNC : In areas where the supply is at

60Hz, you can synchronize the

output phase of multiple cameras

using the power synchronization

function (Line-Lock) without using

a synchronization signal generator.

– INT : Internal Synchronization Type

– L/L : Power Synchronization Type, Line-lock

l

Press the Function Setup switch.

l

You can select a desired phase from 0 to 359 when select ‘phase’.

MOTION DET : You can monitor activity more efficient with this feature

allowing you to observe

movement of objects

in 8 different areas on the

screen, and the words

‘MOTION DETECTED’ appear

on the screen when

movement is detected..

1) When the SPECIAL menu screen is displayed, press the Up and Down

buttons so that the arrow indicates ‘MOTION DET’.

Notes

• When using AC power at 60Hz frequency, you can use the L/L type

synchronization.

• When the power is DC 12V, the SYNC menu is fixed to the ‘INT’ mode.