Clinton Electronics CE-VF540 User Manual
Page 26
Sales: 1-800-447-3306 Support: 1-800-549-6393 www.clintonelectronics.com
23
SYNC : In areas where the supply is at
60Hz, you can synchronize the
output phase of multiple cameras
using the power synchronization
function (Line-Lock) without using
a synchronization signal generator.
– INT : Internal Synchronization Type
– L/L : Power Synchronization Type, Line-lock
l
Press the Function Setup switch.
l
You can select a desired phase from 0 to 359 when select ‘phase’.
MOTION DET : You can monitor activity more efficient with this feature
allowing you to observe
movement of objects
in 8 different areas on the
screen, and the words
‘MOTION DETECTED’ appear
on the screen when
movement is detected..
1) When the SPECIAL menu screen is displayed, press the Up and Down
buttons so that the arrow indicates ‘MOTION DET’.
Notes
• When using AC power at 60Hz frequency, you can use the L/L type
synchronization.
• When the power is DC 12V, the SYNC menu is fixed to the ‘INT’ mode.