Allied Telesis SB251-13 User Manual

Page 10

Advertising
background image

10

Patch Release Note

Patch SB251-13 for Software Release 2.5.1

C613-10361-00 REV M

When typing “?” at the command line after SET SWITCH PORT,
INGRESSLIMIT was incorrectly displayed as a valid option. This issue has
been resolved.

A memory leak was occurring with DHCP. This issue has been resolved.

Uplugging the remote receive port on the 32FX card (AT-SB4352) was
causing the switch to lock-up. This issue has been resolved.

When the speed and duplex settings of a port were configured with the SET
SWITCH PORT SPEED command, the port sometimes erroneously
advertised auto-negotiation capabilities, usually when ports were
configured with a startup script. This issue has been resolved so that switch
ports will not advertise any capabilities when configured with fixed speed
and duplex settings.

When the device was configured as a DHCP server, a fatal error sometimes
occurred when a Telnet session to the device was closed while DHCP was
reclaiming IP addresses. Also, a Telnet error message displayed an incorrect
value when a telnet command line parameter was repeated (for example,
SHOW TELNET TELNET). These issues have been resolved.

Packets were not routed when an IPv6 flow was enabled. This issue has
been resolved.

The switch was adding a router port for multicast packets to destinations
with an address in the range 224.0.0.x. Switch port entries are now only
created for special router multicast addresses.

When the configurable temperature threshold had not been set, its value
should show as “Undefined” in the output of the SHOW SYSTEM
command, but it showed the same value as the fixed temperature threshold.
This issue has been resolved.

A fatal error sometimes occurred during persistent hotswapping of line
cards if the cards were inserted or removed before waiting for a message
like the following examples to appear:

Info (1034266): Board AT-SB4411 8-1000T(RJ45) hot-inserted

Info (1034268): Board AT-SB4411 8-1000T(RJ45) hot-swapped out

This issue has been resolved.

PCR: 03872

Module: SWI

Level: 3

PCR: 03879

Module: DHCP

Level: 2

PCR: 03880

Module: SWICX, SWI

Level: 2

PCR: 03887

Module: SWCX

Level: 2

PCR: 03888

Module: DHCP, TELNET

Level: 2

PCR: 03889

Module: IPV6

Level: 2

PCR: 03890

Module: IGMP, SWI

Level: 2

PCR: 03891

Module: CORE

Level: 3

PCR: 03899

Module: CORE

Level: 2

Advertising