Patch SB251-13 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches

33

Patch SB251-13 for Software Release 2.5.1
C613-10361-00 REV M

RIPng was not sending a response back to a RIP request message. This issue
has been resolved.

IPv4 filters now behave like IPv6 filters.

When the configuration script was created using the CREATE CONFIG
command, the GBLIP parameter in the ADD FIREWALL POLICY
command was listed twice. This caused the command to fail when the
device was restarted. This issue has been resolved.

The action of the MAJOR and MINOR relays
does not presently match the illustration
located alongside their connections.

This issue has been resolved by reversing
the action of the relays in software to match
the illustration shown on the right.

Please check that your alarm relays are still
appropriately connected.

The SET TRACE PORT command was not functioning correctly. Also, the
SHOW CONFIG DYNAMIC PING command was producing an incorrect
output format. These issues have been resolved.

The TRACE command was not working when using an IPv6 link-local
address. This issue has been resolved.

A memory leak occurred when some IPSEC processes failed. This issue has
been resolved.

Parallel forwarding PIM neighbours were not always sending PIM Assert
messages following a neighbour re-boot. This was causing the transmission
of duplicate multicast data. This issue has been resolved.

PIM4 and PIM6 were not sending Hello packets if the HELLOINTERVAL
was not a multiple of 10. This is set with the ADD PIM INTERFACE, ADD
PIM6 INTERFACE, SET PIM INTERFACE, and SET PIM6 INTERFACE
commands. This issue has been resolved.

PCR: 03203

Module: IPV6

Level: 3

PCR: 03206

Module: IPG

Level: 3

PCR: 03208

Module: FIREWALL

Level: 2

PCR: 03209

MODULE: ALARM

Level: 1

PCR: 03210

Module: PING

Level: 4

PCR: 03212

Module: IPV6

Level: 3

PCR: 03213

Module: IPSEC

Level: 3

PCR: 03214

Module: PIM

Level: 2

PCR: 03216

Module: PIM, PIM6

Level: 2

PCR: 03217

Module: DVMRP

Level: 2

ALARM RELAYS

MINOR ALARM

N/O

N/C

COMMON

MAJOR ALARM

N/O

N/C

COMMON

, 1A
, 0.5A

12 VDC
48 VDC

Advertising