connections will now only retry SYNs once after 5 seconds. The round robin
selection algorithm will now select an UP resource in a resource pool with
only one UP resource, even if it was used for the last successful connection.

Sometimes healthcheck pings were not sent to the load balancer resources.
This issue has been resolved.

The system became unstable if the ADD IPV6 TUNNEL command failed.
This instability was caused by the partially created tunnel entry not being
properly removed from the tunnel database. The tunnel entry is now
completely removed.

Invalid routes and packets were occurring within RIP. This issue has been
resolved.

AT-9800 Series switches with 16 ports could be configured beyond their 16
port maximum. Attempting to configure port 17 would produce no error
message, and attempting to configure ports 18 and above would result in an
incorrect error message. Also, the SwitchBlade could be allocated with 17
ports within a single trunk group, one port more than the maximum. These
issues have been resolved; in both instances the maximum port
configuration is now 16.

RIPng was not sending a response back to a RIP request message. This issue
has been resolved.

IPv4 filters now behave like IPv6 filters.

The SHOW SYSTEM SYSR SLAVE COUNT and SHO SYS SYSR SLAVE
commands have been removed from the user command set.

When the configuration script was created using the CREATE CONFIG
command, the GBLIP parameter in the ADD FIREWALL POLICY
command was listed twice. This caused the command to fail when the
device was restarted. This issue has been resolved.

PCR: 03194

Module: LB

Level: 3

PCR: 03196

Module: IPV6

Level: 3

PCR: 03199

Module: IPV6

Level:

PCR: 03201

Module: SWI

Level: 4

PCR: 03203

Module: IPV6

Level: 3

PCR: 03206

Module: IPG

Level: 3

PCR: 03207

Module: Alarm

Level: 4

PCR: 03208

Module: FIREWALL

Level: 2