6. Maintenance

Proper maintenance of the TurfWeather weather station is essential to obtain

accurate data. Equipment must be in good operating condition, which requires

a program of regular inspection and maintenance. Routine and simple

maintenance can be accomplished by the person in charge of the weather

station. Inspect the weather station weekly when first installed to get an

understanding of how often cleaning and inspecting should be performed.

Keep the weather station level for accurate solar radiation and rain

measurements. Use the level bubble located on top of weather station for

reference.

More difficult maintenance such as sensor replacement can be accomplished

with instructions included in this manual, or the TurfWeather station can be

sent to Campbell Scientific if preferred.

6.1 Solar Panel pn SP5

An occasional cleaning of the glass on the solar panel will improve its

efficiency. Use warm mildly soapy water and a clean cloth. Rinse with clean

water.

6.2 Battery Pack pn 14159

The battery pack is a 12 Vdc, 0.8 Ah battery with a special connector. It has a

life expectancy of three to five years. It is located inside the weather station. It

is a sealed lead acid battery design, and if it is discharged below 11.0 volts, it

may become damaged and no longer accept a charge regardless of the age of

the battery. PC200W and most weather software will display the weather

station battery voltage. Typical measurements should be between 12.5 and

13.5 Vdc. See Section 6.9.2, Battery Pack Replacement Procedure, for

instructions on replacement.