Site master pm 5 – Anritsu Site Master S331D User Manual

Page 11

Advertising
background image

Control Byte

#

Name

Description

Watchdog

Timer

106 (6Ah)

Set Spectrum Analyzer

Resolution Bandwidth Freq

Sets the Spectrum Analyzer resolution BW frequency (obsolete)

Yes

107 (6Bh)

Set Spectrum Analyzer

Video Bandwidth Freq

Sets the Spectrum Analyzer video BW frequency (obsolete)

Yes

108 (6Ch)

Set Spectrum Analyzer

Sweep Mode

Sets the Spectrum Analyzer sweep mode

Yes

109 (6Dh)

Set Spectrum Analyzer

Marker to Peak

Sets specified marker to peak value of the sweep

Yes

110 (6Eh)

Set Spectrum Analyzer

Marker to Center

Sets the center frequency equal to the frequency of the specified marker

Yes

111 (6Fh)

Set Spectrum Analyzer

Attenuation

Sets the attenuation for the Site Master Spectrum Analyzer mode (obsolete)

Yes

112 (70h)

Set VNA Segmented Limit

Lines

Sets the position and On/Off status of the segmented limit lines for the VNA

modes

Yes

113 (71h)

Set Spectrum Analyzer

Multiple Limit

Sets the position and On/Off Status of a limit segment for the SPA mode

Yes

114 (72h)

Set Return Spectrum

Analyzer Sweep Time

If this is enabled, the duration of the current sweep (in milliseconds) will be

returned as 4 bytes via the serial port at the end of the sweep

Yes

115 (73h)

Set Reference Level Offset

Sets the value of the reference level offset

Yes

117 (0x75)

Read Marker Value

Returns the frequency location of the specified marker, and the value at that

location

Yes

118 (76h

Set Sweep Averaging

Sets the number of sweeps to average

Yes

120 (78h)

Field InstaCal

Initiates an InstaCal calibration

—-

124 (7Ch)

Read InstaCal Module

ASCII Serial Number

Returns the InstaCal Module serial number in ASCII

Yes

129 (81h)

Set Site Master Marker

(Peak/Valley)

Sets an individual marker in current measurement mode to either peak

(maximum) signal or valley (minimum) signal

Yes

133 (85h)

Set/Reset SPA External

Reference

Sets the external reference frequency for the spectrum analyzer

Yes

134 (86h)

Check External SPA

Reference

Returns the state of the SPA external reference

—-

136 (88h)

Set SPA Preamp State

Sets the state of the SPA preamp

Yes

140 (8Ch)

Set SPA Units

Sets the scale type (logarithmic or linear) and the units

Yes

141 (8Dh)

Set SPA Resolution

Bandwidth

Sets the resolution BW frequency for the Spectrum Analyzer

Yes

142 (8Eh)

Set SPA Video Bandwidth

Sets the video BW frequency for the Spectrum Analyzer

Yes

143 (8Fh)

Set SPA Attenuation

Sets the attenuation for the Spectrum Analyzer

Yes

145 (91h)

Set AM/FM Demod

Sets the AM/FM/SSB Demodulation state

Yes

197 (C5h)

Set Baud Rate

Sets the serial communication baud rate for this session

Yes

198 (C6h)

Set Language

Sets the Site Master display language

Yes

208 (D0h)

Query Time

Queries the Site Master for the current time in ASCII format

—-

221 (DDh)

Read Main Serial Number

Returns the Main (External) Serial Number as four bytes

Yes

255 (FFh)

Exit Remote Mode

Ends serial communications

—-

A001h

Set T1 Transmission Level

Sets the transmission level of T1 measurement mode

Yes

A002h

Set T1/E1 Clock Source

Sets the Clock Source of T1/E1 measurement mode

Yes

A003h

Set T1/E1 Pattern

Sets the data pattern of T1/E1 measurement mode

Yes

Site Master PM

5