Site master pm 35 – Anritsu Site Master S331D User Manual

Page 41

Advertising
background image

150) Start Distance (highest byte)

76

151) Start Distance

152) Start Distance

153) Start Distance (lowest byte)

154) Stop Distance (highest byte)

155) Stop Distance

156) Stop Distance

157) Stop Distance (lowest byte)

158) Distance Marker 1 (higher byte)

77

159) Distance Marker 1 (lower byte)

160) Distance Marker 2 (higher byte)

161) Distance Marker 2 (lower byte)

162) Distance Marker 3 (higher byte)

163) Distance Marker 3 (lower byte)

164) Distance Marker 4 (higher byte)

165) Distance Marker 4 (lower byte)

166) Distance Marker 5 (higher byte)

167) Distance Marker 5 (lower byte)

168) Distance Marker 6 (higher byte)

169) Distance Marker 6 (lower byte)

170) Relative Propagation Velocity (highest byte)

78

171) Relative Propagation Velocity

172) Relative Propagation Velocity

173) Relative Propagation Velocity (lowest byte)

174) Cable Loss (highest byte)

79

175) Cable Loss

176) Cable Loss

177) Cable Loss (lowest byte)

178) Status Byte 1: ( 0b = Off , 1b = On)

(LSB)

bit 0 : Marker 1 On/Off

bit 1 : Marker 2 On/Off

bit 2 : Marker 3 On/Off

bit 3 : Marker 4 On/Off

bit 4 : Marker 5 On/Off

bit 5 : Marker 6 On/Off

bits 6-7 : Not Used

179) Status Byte 2: (0b = Off, 1b = On)

(LSB)

bit 0 : Marker 2 Delta On/Off

bit 1 : Marker 3 Delta On/Off

bit 2 : Marker 4 Delta On/Off

bits 3-7: Not Used

180) Status Byte 3: (0b = Off , 1b = On)

80

(LSB)

bit 0 : Single Limit On/Off

bit 1: CW On/Off

bits 2-3: Not Used

bit 4 : InstaCal On/Off

Site Master PM

35

76 Distance data uses units 1/100,000m or 1/100,000 ft

77 Marker point = ( # of data points – 1 ) * ( marker dist – start dist ) / ( stop dist – start dist )

78 Relative Propogation Velocity uses units 1/100,000

79 Cable Loss uses units 1/100,000 dB/m or 1/100,000 dB/ft

80 Bits (4,5) are as follows: (0,0)=Cal Off, (0,1)=OSL Cal, (1,0) = Impossible, (1,1) = InstaCal

Advertising
This manual is related to the following products: