Site master pm 41 – Anritsu Site Master S331D User Manual

Page 47

Advertising
background image

45) Spectrum Analyzer Minimum Frequency Step Size

46) Spectrum Analyzer Minimum Frequency Step Size

47) Spectrum Analyzer Minimum Frequency Step Size (lowest byte)

48) Ref Level (highest byte)

98

49) Ref Level

50) Ref Level

51) Ref Level (lowest byte)

52) Scale per div (highest byte)

99

53) Scale per div

54) Scale per div

55) Scale per div (lowest byte)

56) Spectrum Analyzer Frequency Marker 1 (higher byte)

100

57) Spectrum Analyzer Frequency Marker 1 (lower byte)

58) Spectrum Analyzer Frequency Marker 2 (higher byte)

59) Spectrum Analyzer Frequency Marker 2 (lower byte)

60) Spectrum Analyzer Frequency Marker 3 (higher byte)

61) Spectrum Analyzer Frequency Marker 3 (lower byte)

62) Spectrum Analyzer Frequency Marker 4 (higher byte)

63) Spectrum Analyzer Frequency Marker 4 (lower byte)

64) Spectrum Analyzer Frequency Marker 5 (higher byte)

65) Spectrum Analyzer Frequency Marker 5 (lower byte)

66) Spectrum Analyzer Frequency Marker 6 (higher byte)

67) Spectrum Analyzer Frequency Marker 6 (lower byte)

68) Spectrum Analyzer Single Limit (highest byte)

101

69) Spectrum Analyzer Single Limit

70) Spectrum Analyzer Single Limit

71) Spectrum Analyzer Single Limit (lowest byte)

72) SPA Multiple Upper Limit 1 Start X

102

(highest byte)

73) SPA Multiple Upper Limit 1 Start X

74) SPA Multiple Upper Limit 1 Start X

75) SPA Multiple Upper Limit 1 Start X (lowest byte)

76) SPA Multiple Upper Limit 1 Start Y (Power Level) (highest byte)

103

77) SPA Multiple Upper Limit 1 Start Y (Power Level)

78) SPA Multiple Upper Limit 1 Start Y (Power Level)

79) SPA Multiple Upper Limit 1 Start Y (Power Level) (lowest byte)

80) SPA Multiple Upper Limit 1 End X

104

(highest byte)

81) SPA Multiple Upper Limit 1 End X

82) SPA Multiple Upper Limit 1 End X

83) SPA Multiple Upper Limit 1 End X (lowest byte)

84) SPA Multiple Upper Limit 1 End Y (Power Level) (highest byte)

105

85) SPA Multiple Upper Limit 1 End Y (Power Level)

86) SPA Multiple Upper Limit 1 End Y (Power Level)

Site Master PM

41

98 Value sent as (value in dBm * 1000) + 270,000)

99 Value sent as (value * 1000)

100 Value sent as data point on the display. Equivalent frequency = (point * span / ( # data points – 1 ) ) + start frequency.

101 Value sent as ( value in dBm * 1000 ) + 270000

102 Scaled by Frequency Scale Factor (bytes 321-322)

103 Value sent as ( value in dBm * 1000 ) + 270000

104 Scaled by Frequency Scale Factor (bytes 321-322)

105 Value sent as ( value in dBm * 1000 ) + 270000

Advertising