44 site master pm – Anritsu Site Master S331D User Manual

Page 50

Advertising
background image

286) Trigger Type

117

287) Interference Analysis Frequency

118

(highest byte)

288) Interference Analysis Frequency

289) Interference Analysis Frequency

290) Interference Analysis Frequency (lowest byte)

291) Trigger Position (0 – 100%)

292) Min Sweep Time (in ms) (highest byte)

293) Min Sweep Time (in ms)

294) Min Sweep Time (in ms)

295) Min Sweep Time (in ms) (lowest byte)

296) Video Trigger Level

119

(highest byte)

297) Video Trigger Level

298) Video Trigger Level

299) Video Trigger Level (lowest byte)

300) Status Byte 8

(LSB)

bit 0: Input Power Status (1b = Input Power Too High, 0b = Input Power Ok)

bits 1-7: Not Used

301) Status Byte 9

(LSB)

bits 0-6: Number of sweeps to average (1-25, 1 implies averaging OFF)

bit 7: Not Used

302) Status Byte 10: (0b = Off, 1b = On)

(LSB)

bits 0-1: Trace Math Operation (00b = A only, 01b = A-B, 10b = A+B)

bit 2: Max Hold On/Off

bit 3: Min Hold On/Off

bits 4-7: Not Used

303) Impedance (00h = 50W, 0Ah = 75W Anritsu Adapter, 0Ch = 75W Other Adapter)

304) Impedance Loss

120

(higher byte)

305) Impedance Loss (lower byte)

306) AM/FM Demod Type

121

307) AM/FM Demod Status (01h = On, 00h = Off)

308) AM/FM Demod Volume (0 to 100)

309) AM/FM Demod Frequency (highest byte)

122

310) AM/FM Demod Frequency

311) AM/FM Demod Frequency

312) AM/FM Demod Frequency (lowest byte)

313) AM/FM Demod Time (in ms) (highest byte)

314) AM/FM Demod Time (in ms)

315) AM/FM Demod Time (in ms)

316) AM/FM Demod Time (in ms) (lowest byte)

317) SSB BFO Offset

123

(highest byte)

318) SSB BFO Offset

319) SSB BFO Offset

320) SSB BFO Offset (lowest byte)

44

Site Master PM

117 Trigger Type – 00h = Single, 01h = Free Run, 02h = Video, 03h = External

118 Scaled by Frequency Scale Factor (bytes 321-322)

119 Value sent as ( value in dBm * 1000 ) + 270,000

120 Value sent as (value in dB * 1000), valid values are 0 to 20 dB

121 AM/FM Demod Type: 00h = FM-Wide Band, 01h = FM-Narrow Band, 02h = AM, 03h = SSB Lower, 04h = SSB Upper

122 Scaled by Frequency Scale Factor (bytes 321-322)

123 Value sent as ((value in Hz) – 10,000)

Advertising