46 site master pm – Anritsu Site Master S331D User Manual

Page 52

Advertising
background image

51) Power Meter Relative

52) Power Meter Relative

53) Power Meter Relative (lowest byte)

54) Power Meter Status (00h = Off, 01h = On)

55) Power Meter Unit (00h = Watts, 01h = dBm)

56) Power Meter Relative Status (00h = Off, 01h = On)

57) Power Meter Offset Status (00h = Off, 01h = On)

58) Power Meter RMS Averaging Level (00h = Off, 01h = Low, 02h = Medium, 03h = High)

59) Frequency Scale Factor

135

(higher byte)

60) Frequency Scale Factor (lower byte)

61) Frequency Range Minimum

136

(highest byte)

62) Frequency Range Minimum

63) Frequency Range Minimum

64) Frequency Range Minimum (lowest byte)

65) Frequency Range Maximum

137

(highest byte)

66) Frequency Range Maximum

67) Frequency Range Maximum

68) Frequency Range Maximum (lowest byte)

69) Zero Status (00h = Off, 01h = On)

70) Zero Value

138

(highest byte)

71) Zero Value

72) Zero Value

73) Zero Value (lowest byte)

74-120) Not Used

For T1 Mode (Option 50):

26) T1 Receive Input (00h: Terminate, 01h: Bridged, 02h: Monitor)

27) T1 Framing Mode (01h: ESF, 02h: D4SF)

28) T1 Line Coding (01h: B8ZS, 02h: AMI)

29) T1 Clock Source (00h: External, 01h: Internal)

30) T1 Tx Level (01h: 0 dB, 02h: -7.5 dB, 03h: -15 dB)

31) T1 Error Insert Type (00h: Frame Error, 01h: BPV, 02h: Bit Errors, 04h: RAI, 05h: AIS)

32) T1 Loop Code (00h: CSU, 01h: NIU, 02h: User 1, 03h: User 2)

33) T1 CRC Method (00h: ANSI CRC, 01h: Japanese CRC)

34) T1 Loop Type (00h: In Band, 01h: Data Link)

35) T1 Pattern (higher byte)

36) T1 Pattern (lower byte) 01h: PRBS-9, 02h: PRBS-11, 03h: PRBS-15, 04h: PRBS-20(O.151), 05h:

PRBS-20(O.153), 06h: PRBS-23, 07h: QRSS, 08h: 1 in 8, 09h: 2 in 8, 0Ah: 3 in 8, 0Bh: All Ones, 0Ch: All

Zeros, 0Dh: T1-DALY, 0Eh: User Defined)

37) T1 Pattern Invert Status (00h: Non-Inverted, 01h: Inverted)

38) T1 Display Type (00h: Histogram, 01h: Raw Data)

39) T1 Impedance

40 - 55) First User Defined Loop Code Down (16 bytes)

56 - 71) Second User Defined Loop Code Down (16 bytes)

72 - 87) First User Defined Loop Code Up (16 bytes)

88 - 103) Second User Defined Loop Code Up (16 bytes)

104 - 135) User Defined Pattern (32 bytes)

136) T1 1

st

User Defined Loop Up (higher byte)

46

Site Master PM

135 In number of Hz

136 Scaled by Frequency Scale Factor

137 Scaled by Frequency Scale Factor

138 Value sent as ((value in dBm * 1000) + 100)

Advertising