Write custom cable œ control byte #80 (50h) 77, Recall custom cable œ control byte #81 (51h) 77 – Anritsu Site Master S331D User Manual

Page 83

Advertising
background image

1-2) Model # (unsigned integer, 14h for Site Master S331D, 15h for Site Master S332D)

3-9) Extended Model # (7 bytes in ASCII)

10-13) Software Version (4 bytes in ASCII)

Write Custom Cable – Control Byte #80 (50h)

Description: Write a cable parameter in the custom cable list.

Bytes to Follow: 25 bytes

1)

Not Used

2)

Cable List index (0 - 49)

3 – 17) Cable Description (string)

18) Propagation Velocity (highest byte)

264

19) Propagation Velocity

20) Propagation Velocity

21) Propagation Velocity (lowest byte)

22) Insertion Loss (highest byte)

265

23) Insertion Loss

24) Insertion Loss

25) Insertion Loss (lowest byte)

Site Master Returns: 1 byte

1)

255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error

238 (EEh) Time Out Error

Recall Custom Cable – Control Byte #81 (51h)

Description: Query a cable in the custom cable list.

Bytes to Follow: 2 bytes

1)

Not Used

2)

Cable list index (0-49)

Site Master Returns: 24 bytes

1)

Upper bound of Custom Cable Index

2 – 16) Cable Description (string)

17) Propagation Velocity (highest byte)

266

18) Propagation Velocity

19) Propagation Velocity

20) Propagation Velocity (lowest byte)

21) Insertion Loss (highest byte)

267

22) Insertion Loss

23) Insertion Loss

24) Insertion Loss (lowest byte)

Site Master PM

77

264 Cable loss uses units 1/100,000 dBm or 1/100,000 dB/ft.

265 Relative Propagation Velocity uses units 1/100,000.

266 Relative Propagation Velocity uses units 1/100,000.

267 Cable loss uses units 1/100,000 dB/m or 1/100,000 dB/ft.

Advertising
This manual is related to the following products: