An electrical wiring diagram is located behind the

control panel on the left side of the oven. This

appliance must be branch circuit protected with proper

ampacities, in accordance with the wiring diagram

located in the electrical compartment of the oven.

Wire size for the main incoming power to the unit

must match the minimum size listed in the

specifications applicable to the specific oven model.

For supply connections, locate the wire size posted on

the label located on the electrical control box cover,

behind the service panel.

Before operating the oven, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.

NOTE: After both water and electrical connections

have been completed, operate the oven in

any cooking mode for a period of 15 minutes

and recheck the main power connections at

the terminal block to make certain they

remain tight.

G A S C O M B I T H E R M

I N S T A L L A T I O N M A N U A L

#MN-28898

PG

. 14

®

C O M B I T HE R M

E L E C T R I C A L & I N S TA L L AT I O N R E Q U I R E M E N T S

MODEL

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

KW

CIRCUIT

AWG

6•10esG

110-120

1

50/60

5.7

.68

20 A

2

WIRE

PLUS GROUND

6•10esG/

SK

110-120

1

50/60

9.5

1.14

20 A

AWG

12

7•14esG

110-120

1

50/60

5.7

.68

20 A

2

WIRE

PLUS GROUND

7•14esG/

SK

110-120

1

50/60

9.5

1.14

20 A

AWG

12

10•10esG

110-120

1

50/60

5.7

.68

20 A

2

WIRE

PLUS GROUND

10•10esG/

SK

110-120

1

50/60

9.5

1.14

20 A

AWG

12

10•20esG

110-120

1

50/60

7.8

.936

20 A

2

WIRE

PLUS GROUND

AWG

12

12•18esG

110-120

1

50/60

7.8

.936

20 A

2

WIRE

PLUS GROUND

AWG

12

20•20esG

110-120

1

50/60

22.0

2.64

30 A

2

WIRE

PLUS GROUND

AWG

10

OTHER VOLTAGES AVAILABLE

: Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz

380-415V:

To prevent an electrical shock hazard

between the appliance and other appliances

or metal parts in close vicinity, an

equalization-bonding stud is provided.

An equalization bonding lead must be

connected to this stud and the other

appliances / metal parts to provide

sufficient protection against potential

difference. The terminal is marked with

the following symbol.

D A N G E R

ELECTRICAL GROUNDING
INSTRUCTIONS:

This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.

D A N G E R

AVERTISSEMENT:

Directives

pour la prise de courant électrique Cet
appareil est muni d'une fiche à trios
branches (prise de Courant) afin de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fiche.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.