E R R O R C O D E S

®

C O M B I T HE R M

In the event of an error code, the Combitherm may be operated on a limited basis. Error conditions under
which continued operation can be conducted are indicated by “Yes” in the chart shown below.

When the oven malfunctions, an error code will appear in the display.

PRESS THE START KEY TO ACKNOWLEDGE THE ERROR.

The keys that begin to flash represent operational modes that are still usable.

SELECT AND PRESS ONE OF THE COOKING MODES INDICATED.

The oven control will only respond to the mode keys that are flashing.

SET THE OVEN CONTROLS AS IF OPERATING UNDER NORMAL CIRCUMSTANCES.

Depending on the error code involved, oven function, such as temperature range, may be limited.

PRESS THE START KEY TO BEGIN THE COOKING PROCESS.

PRESS THE START KEY WHEN THE TIMER EXPIRES.

When the oven fault is corrected, the Combitherm will return to normal Operation.

CONTINUED OPERATION UNDER ERROR CONDITIONS

E M E R G E N C Y O P E R A T I O N

Error

Code

Display Shows

ES

ESi

Steam

Mode

Combination

Mode

Convection

Mode

Rether m

Mode

E01

Low Water

Yes

No

No

No

To 365°F

No

E02

Control Temp High

Yes

Yes

Yes

To 284°F

To 284°F

To 284°F

E03

Fan Malfunction

No

No

E04

Aux Fan Fault

Yes

Yes

Yes

To 284°F

To 284°F

To 284°F

E11

Excess Oven Temp

Yes

Yes

No

No

No

No

E13

Excess Steam Gen Temp

Yes

No

No

No

No

No

E15

Excess Condensate Temp

Yes

Yes

No

No

To 356°F

No

E21

Oven Probe Fault

Yes

Yes

212°F only

No

No

No

E22

Core Temp Probe Fault

Yes

Yes

Yes

Yes

Yes

Yes

E23

Steam Gen Probe Fault

Yes

No

Yes

Yes

Yes

Yes

E24

Bypass Probe Fault

Yes

Yes

To 210°F

No

Yes

No

E25

Condensate Probe Fault

Yes

Yes

Yes

To 356°F

To 356°F

To 320°F

E26

Steam Gen Safety Probe Fault

Yes

No

Yes

Yes

Yes

Yes

E27

Excess Steam Gen Safety Temp

Yes

No

No

No

No

No

E29

Probe Short to Frame

Yes

Yes

No

No

No

No

E34

DE (Drain) Pump Failure

Yes

No

Yes

Yes

Yes

Yes

E35

Venting Error

Yes

Yes

Yes

Yes

Yes

Yes

E36

Steam Temp High

No

Yes

No

No

Yes

No

E80

ID Error

Yes

Yes

Yes

Yes

Yes

Yes

E81

Program Memory Error

Yes

Yes

Yes

Yes

Yes

Yes

E82

WP Error

Yes

Yes

Yes

Yes

Yes

Yes

E83

Algo Error

Yes

Yes

Yes

Yes

Yes

Yes

E96

Connection Error