background image

G A S C O M B I T H E R M

I N S T A L L A T I O N M A N U A L

#MN-28898

PG

. 18

G A S S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S

®

C O M B I T HE R M

The minimum size requirement for gas piping or a

flexible connector is

3/4

- inch (19mm). For long runs

of gas piping, the pipe diameter must conform to the

tables in the National Fuel Gas Code, ANSI/NFPA

Z223.1.
A listed gas shut-off valve must be installed

upstream of the appliance to shut off the gas supply

during servicing. The shut-off valve should be

accessible with the appliance in the normal

installation position.
If the oven or the oven stand is supplied with

casters, gas connection must be made with a flexible

connector that complies with the Standard for

Connectors for Movable Gas Appliances, ANSI

Z21.69; or in Canada, Connectors for Movable Gas

Appliances, CAN/CGA-6.16-M87. When using a

flexible connector, a quick disconnect device must

be used to comply with the Standard for Quick-

Disconnect Devices for Gas Fuels, ANSI Z21.41; or

in Canada, Quick Disconnect Devices for Use with

Gas Fuels, CAN1-6.9.
When a quick disconnect device and flexible

connector are used, a restraining device must be

installed to limit the movement of the appliance and

prevent damage to the connector or quick

disconnect. An example of a restraining device

would consist of a 2000 pound test, stainless steel

cable, attached to a structural member of the kitchen

wall behind the oven. The means of attachment

should consist of a q u i c k c o n n e c t s n a p s o t h a t

t h e o v e n c a n b e disconnected when the appliance

must be moved away from the wall.
The other end of the cable should be permanently

attached to the rear frame of the oven. The cable

should be of sufficient length so that no strain is

ever placed on the flexible gas connector in the

event of accidental movement of the oven without

properly disconnecting the gas connector. The

flexible connector should be routed to form a

downward "U" loop between the building gas

supply and the permanent attachment at the rear of

the oven.
The routing of the flexible connector must not be

made under the oven. Oven temperatures achieved

during operation are too hot for safe operation. Gas

piping should be installed from the point of gas

connection at the bottom, front of the oven to the

back of the oven where the flexible connector may

be safely used. See the illustration for the

recommended placement.

W A R N I N G

GAS PIPING MUST NEVER

BE INSTALLED TO RUN

UNDER THE BURNER

.