Alto-Shaam 12.18ESG User Manual

Page 26

Advertising
background image

G A S C O M B I T H E R M

I N S T A L L A T I O N M A N U A L

#MN-28898

PG

. 24

®

C O M B I T HE R M

Use this list as a final check of oven installation conformance. Damage directly attributed to improper set up, installation,

or cleaning can invalidate warranty claims.

C L E A R A N C E S :

Left:

6” (152mm) — Service access of 18” (457mm) recommended.

20” (508mm) from heat producing equipment.

Right: 4” (102mm)

Back:

4” (102mm) for plumbing

Top:

20” (508mm) for air movement

ARE ALL CLEARANCE
REQUIREMENTS MET?

YES

NO

IF NO, EXPLAIN: ________________________

________________________________________

WAT E R S U P P LY A N D D R A I N S :

Verify hook-up to TWO (2) separate cold water supply lines with a

3

/

4

" (19mm)

water connection supply line. Verify inlet water pressure is at a minimum of 30 PSI

(2.8 bar). Maximum water pressure is not to exceed 90 PSI (6 bar). Verify drain

diameter of 1-1/2" (41mm) with a positive descending slope, and with a 2" (51mm)

air gap which is free of obstructions before connection to the site drain. Verify 1/8"

(3,2mm) pitch to 10' (305cm) of drain line.

IMPORTANT: Alto-Shaam has listed Water Quality Requirements in the

installation manual for this equipment. It is the responsibility of the end user

to have the water connected to this appliance tested to ensure these standards

are met before putting the oven into use. Failure to meet these standards will

void the warranty if damage to the oven is found to be related to water quality.

ARE BOTH WATER SUPPLY LINES

PROPERLY CONNECTED?

YES

NO

IF NO, EXPLAIN: __________________________
IS A FILTER SYSTEM INSTALLED

ON THIS UNIT?

YES

NO

STORE HAS SEEN THIS

RECOMMENDATION:

YES

NO

SIGNATURE OF STORE REPRESENTATIVE:

___________________________________________

C O N T RO L B OA R D C O N N E C T I O N S & O P E R AT I O N :

With the Power Key

OFF

, press and hold the Chef Function

Key to access software version, and record.

ALL BOARD CONNECTIONS TIGHT:

YES

NO

ALL FUNCTIONS LIGHT UP:

YES

NO

ALL FUNCTIONS ON CONTROL OPERATE:

YES

NO

UNIT OPERATES IN ALL MODES:

YES

NO

IF NO, EXPLAIN: ________________________________________

P H Y S I C A L C O N D I T I O N : *

R E F E R E N C E I N S TA L L AT I O N I N S T R U C T I O N S F O R C O M P L E T E I N F O R M AT I O N

Bottom of oven has been checked for damage due to improper positioning on site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Verify all gaskets, hoses, and carts* are in place and function properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

If oven includes a cart, verify proper installation of the rack guide* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Verify the installation of drip pans*, racks, shelves, drain screen, spray hose* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Verify the oven is level and installed on a solid, water resistant floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E L E C T R I C A L C O N N E C T I O N S :

Verify electrical power
requirements for oven.
Verify voltage at terminal
block. Check all terminals
for tightness.

LINE VOLTAGE AT TERMINAL BLOCK (

TO GROUND

):

LINE 1: _________ LINE 2:_________ LINE 3: _________

LINE VOLTAGE (

PHASE TO PHASE

): LINE 1 to 2: __________

LINE 2 to 3: __________
LINE 3 to 1: __________

ELECTRICAL SUPPLY LINE SIZE: ______________

CORRECT MOTOR ROTATION:

YES

NO

ALL ELECTRICAL TERMINALS TIGHT:

YES

NO

VOLTAGE: ______________

PHASE: ______________

BREAKER SIZE: ______________

G A S C O N N E C T I O N S ( G A S U N I T S O N LY ) :

Verify that gas connections are 3/4" NPT pipe or 3/4" commercial

flexible gas connector. Verify incoming gas pressure is at least 5.5"

WC for natural gas and 9" WC for propane. Verify that gas valve

outlet pressure is 3.4" WC for natural gas and 5.6" WC for propane.

Verify that if a commercial flexible gas connector is used that it is not

run under the oven, but connected at the rear of the oven.

NATURAL GAS

PROPANE

GAS CONNECTION: __________

INCOMING GAS PRESSURE: __________

GAS OUTLET PRESSURE: __________

CONNECTION AT REAR OF OVEN: __________

SOFTWARE VERSION:

BM_____________ SM_____________ KM_____________

SERVICE AGENCY

:

START

-

UP DATE

:

INSTALLATION NAME

:

MODEL NO

.:

SERIAL NO

.:

TECH SIGNATURE

:

CUSTOMER SIGNATURE

:

I N S TA L L AT I O N C H E C K L I S T