10

VERTICAL CONTACT TOASTER

P/N 1010719 Rev. E 02/13

TEMPERATURE CONTROL PANEL

NOTE: Setpoint Temperature refers to the desired

temperature setting.
Pressing the TEMP UP key will display the current plat-

en heater temperature providing the platen temperature

is over 400°F (204°C).

Pressing the TEMP DOWN key will display the current

auxiliary heaters temperature providing the auxiliary

heaters temperature is over 300°F (148°C).

Pressing TEMP SCALE key will switch the temperature

display between Fahrenheit (°F) and Celsius (°C).

PLATEN HEATER TEMPERATURE ADJUSTMENT

1. Turn rocker switch on and wait for temperature

display to finish the power up sequence (Figure

7).

2. Press and hold both TEMP UP and TEMP DOWN

keys for over 1 second until the display flashes

the setpoint temperature, then release (Figure 8).

3. Press the TEMP UP key to raise the setpoint tem-

perature or press the TEMP DOWN key to lower

the setpoint temperature. The setpoint tempera-

ture will adjust 1° every 0.1 seconds.

4. Release the key when the desired setpoint is dis-

played.

NOTE: If no change is made within 5 seconds, the

display will revert back to the previous setpoint.

AUXILIARY HEATER TEMPERATURE ADJUSTMENT

1. Turn rocker switch on and wait for temperature

display to finish the power up sequence (Figure

7).

2. Press and hold both TEMP UP and TEMP SCALE

keys for over 1 second until the display flashes

the setpoint temperature, then release (Figure 9).

3. Press the TEMP UP key to raise the setpoint tem-

perature or press the TEMP DOWN key to lower

the setpoint temperature. The setpoint tempera-

ture will adjust 1° every 0.5 seconds. Continuing

to depress the key for over two consecutive sec-

onds will increase the adjustment speed 1° every

0.1 seconds.

4. Release the key when the desired setpoint is dis-

played.

NOTE: If no change is made within 5 seconds, the

display will revert back to the previous setpoint.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

SP - P

560

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

340

SP - A

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

560

SP - P

FIGURE 7. TEMPERATURE POWER UP SEQUENCE

3. SP-A (Setpoint Auxiliary)

is displayed

1. SP-P (Setpoint Platen)

is displayed

“Heat On” LED will blink on/off during warm-up and when

either platen or auxiliary heaters are calling for heat.

2. Current Platen Temperature

setting is shown

4. Current Auxiliary

Temperature setting is shown

5. “LO” is displayed until

platen temperature rises

above 520°F (271°C)

6. Setpoint is displayed when

Platen Setpoint Temperature*

is reached

* Platen setpoint temperature must be between

520°F (271°C) and 590°F (310°).

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

560

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

LO

OPERATION (continued)

Advertising
This manual is related to the following products: