Vertical contact toaster – A.J. Antunes & Co VCT-20 9200552 User Manual

Page 21

Advertising
background image

21

VERTICAL CONTACT TOASTER

P/N 1010719 Rev. E 02/13

Product is under-toasted or

platen heat is too low or

drop time is too fast

(continued).

Product is getting stuck or

conveyor belts stop when

product is toasting.

Temperature display control or platen

inoperative.

Conveyor drive motor inoperative or
incorrect conveyor motor installed in
toaster.

Bun adjustment controls set

incorrectly.

Conveyor belt wrap missing or not

installed properly.

Conveyor belt wrap or release sheet

not clean.

Not enough voltage, defective power

cord or rocker switch.

To check temperature display control, allow

unit to warm up for 30 minutes, then:

1. Check platen temperature at the center

of platen (with conveyor belt wrap, con-

veyor belt, tensioners and release sheet

removed). Use a pyrometer to confirm

temperature readings.

2. After platen temperature reaches a maxi-

mum of

559° -561°F (292°- 293°C) and

auxiliary heaters reach a maximum of

339°- 341°F (170°- 172°C), and the tem-

perature begins to drop, the heat indica-

tor light on the temperature control board

should turn on. If test readings do not

agree with these figures, replace temper-

ature display control.

To check platen:

Use an Ohm meter to test resistance of the

platen heater (disconnect 1 wire to isolate

heater). Correct cold resistance for heating

element of platen is 17.81 Ohms at

208V/2550 Watts. The auxiliary heaters are

108.2 Ohms at 208V/400 Watts.

To check drive motor:

1. Measure resistance of motor coil.

Replace motor if coil measures either

open circuit or zero resistance.

2. Mark the drive motor sprocket and count

the turns per minute. Correct drive motor

speed is

nine (9) turns per minute.

Measure bun thickness and set bun adjust-

ment controls correctly (page 8).

Install conveyor belt wrap properly (page

13).

Clean respective items. Refer to

Maintenance Schedule (page 11)

Check receptacle for correct voltage. See

Specifications (page 4).

With unit plugged in and rocker switch on,

check for correct voltage into rocker switch.

If low or zero voltage, replace power cord.

If voltage is correct, check for correct volt-

age out of rocker switch. If low or no volt-

age, replace rocker switch.

Problem

Possible Cause

Corrective Action