VERTICAL CONTACT TOASTER

P/N 1010719 Rev. E 02/13

Temperature display shows

“PO”.

Crown and/or heel must be

forced into toaster.

Conveyor belt wrap does

not fit, is difficult to install or

is not long enough.

Temperature display flashes

“HI” and “LO” at cold start-

up.

Temperature display flashes
“HI” and the platen setpoint
temperature.

Unit is receiving low voltage, below

190 VAC.

Heat shield improperly installed or

damaged.

Conveyor belt wrap not tacky.

Crown and/or heel improperly insert-

ed into toaster.

Release sheet is sticky and not

smooth.

Conveyor belt wrap is installed

improperly.

Conveyor belt wrap is damaged.

Auxiliary thermocouple is disconnect-

ed or “Open”.

Faulty control board.

Auxiliary thermocouple is disconnect-

ed or “Open”.

Faulty control board.

Faulty auxiliary solid state relay.

Turn rocker switch off, then on. If display

shows “PO” again, check power cord, power

cord plug and receptacle for damage.

Replace as required.

Remove and reposition heat shield or

replace it.

Clean or replace conveyor belt wrap.

Buns must be inserted with cut faces facing

each other; heel in front slot and crown in

rear slot.

Clean or replace release sheet.

Check to be sure conveyor belt wrap is not

placed over upper support rod. Be sure the

open end of the flap is away from direction

and rotation, and is located toward the out-

side of the conveyor belt wrap.

Replace conveyor belt wrap.

Reattach or replace auxiliary thermocouple.

Replace control board.

Reattach or replace auxiliary thermocouple.

Replace control board.

Replace solid state relay.

Problem

Possible Cause

Corrective Action