Vertical contact toaster – A.J. Antunes & Co VCT-20 9200552 User Manual

Page 23

Advertising
background image

23

VERTICAL CONTACT TOASTER

P/N 1010719 Rev. E 02/13

Conveyor belts are

“jumping” or “snapping”.

(continued).

Temperature display flashes

“LO”.

Temperature display flashes

“HI”.

Conveyor belts installed incorrectly.

Conveyor belt too loose (40 links

required when new). When new, con-

veyor has 38 large links and 2 small

links.

Roller tensioner assy(s). bent or

missing.

Platen temperature is below 420°F

(216°C).
Defective solid state relay.

Heater Platen is “OPEN”.

Faulty control board.

Platen thermocouple is disconnected

or open.

Defective solid state relay.

Platen temperature is over 591°F

(310°C).

Defective control board.

Install conveyor belt to match diagram in

Fig. 17 (page 13). Be sure that ends of the

hooks are facing down.

Remove conveyor belt (page 13). Lay belt

flat and count links. Replace entire belt if

links are damaged. If conveyor belt has too

much play, it will jam. Adjust belt length as

described under Servicing the Conveyor

Belt (page 13).

Replace roller tensioner assy(s). (29, page

26) or tensioners (4, page 30) if damaged

or loose. Replace slide rails (40, page 30) if

worn or missing.

Allow 20 minutes for warm-up and recheck

display.

Replace solid state relay.

To check platen:

Use an Ohm meter to test resistance of the

platen heater (disconnect 1 wire to isolate

heater). Correct cold resistance for heating

element of platen is 17.81 Ohms at

208V/2550 Watts. The auxiliary heaters are

108.2 Ohms at 208V/400 Watts.

Replace control board.

Reattach or replace platen thermocouple.

Replace solid state relay.

See Fault Messages (pages 10 & 11).

Replace control board.

Problem

Possible Cause

Corrective Action