VERTICAL CONTACT TOASTER

P/N 1010719 Rev. E 02/13

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-

ment should be performed by qualified service personnel. The unit should be unplugged when servicing,

except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will

be exposed.

No heat and conveyor belts

do not move.

No heat and conveyor belts

move.

Toaster is installed incorrectly.

No voltage, defective power cord,

defective rocker switch.

Hi-limit switch tripped open.

Wiring problem.

Wiring problem.

Inoperative temperature display

control or platen.

Perform installation and operating proce-

dures (pages 6-11).

Check receptacle for correct voltage. See

Specifications (page 4).

With unit plugged in and rocker switch on,

check for correct voltage into rocker switch.

If low or zero voltage, replace power cord.

If voltage is correct, check for correct volt-

age out of rocker switch. If low or no volt-

age, replace rocker switch.

Reset hi-limit switch (Fig. 5, page 8).

Check all electrical connections for burns,

discoloration or arcing. Replace all connec-

tions or components with damaged termi-

nals. Replace all damaged wiring with the

same (or higher) rated wire.

Check all electrical connections for burns,

discoloration or arcing. Replace all connec-

tions or components with damaged termi-

nals. Replace all damaged wiring with the

same (or higher) rated wire.

To check temperature display control, allow

unit to warm up for 30 minutes, then:

1. Check platen temperature at the center

of platen (with conveyor belt wrap, con-

veyor belt, tensioners and release sheet

removed). Use a pyrometer to confirm

temperature readings.

2. After platen temperature reaches a maxi-

mum of

559°- 561°F (292°- 293°C) and

auxiliary heaters reach a maximum of

339°- 341°F (170°- 172°C), and the tem-

perature begins to drop, the heat indica-

tor light on the temperature control board

should turn on. If test readings do not

agree with these figures, replace temper-

ature display control.