Vertical contact toaster, Vertical contact toaster vct-20, Maintenance (continued) – A.J. Antunes & Co VCT-20 9200552 User Manual

Page 16

Advertising
background image

16

VERTICAL CONTACT TOASTER

P/N 1010719 Rev. E 02/13

Rear Conveyor Cover Assy.

Weld Screws

Tape

Acorn Nuts

Spacers

Tensioner Assy.

Figure 15. Replacing Roller Tensioner Assy.

5. Place one drop of treadlocker into each threaded

hole in the gear reducer casting. Attach the drive

motor bracket to the gear reducer using the origi-

nal four 10-32 x 3/8" screws (310P154) removed

in step 3.

6. Attach the motor sprocket to the gear reducer as

shown in Figure 16.

NOTE: Be sure sprocket setscrew is positioned on

the flat of the gear reducer shaft. Maintain the

3/16" dimension as shown in Figure 17. Apply

threadlocker to threads of setscrew and tighten

securely.
7. Using the four new 8-32 x 5/16" stainless steel

SEMS truss head screws (P/N 308P151), attach

the drive motor bracket to the mounting bracket.

DO NOT tighten screws at this time.

8. Place the drive chain on the sprocket and push

down on motor. Allow 1/4" (0.6 mm) play at mid-

dle of drive chain, then tighten mounting screws

while holding motor. Check drive chain play after

tightening screws.

9. Re-connect motor wires, one at a time.

10. Re-install control cover.

Apply only 1 drop of threadlocker to front of fan assy. after

assembly. Outer edge of fan blade hub to be flush with end of

motor shaft.

3/16"

(4.75 mm)

Apply threadlocker on setscrew of sprocket and all other

mounting screws.

Figure 17. Replacing Drive Motor and Fan Blade

MAINTENANCE (continued)

Figure 16. Replacing Drive Motor and Fan Blade

POW

ER

TEMP

DOWN

TEMP

UP

TEMP

SCALE

˚C

˚F

Fan Blade

Motor Sprocket

Drive Motor/Gear Reducer - Place 1 drop of

threadlocker into each threaded mounting

hole of reducer before installing.

Drive Motor

Bracket

Mounting

Bracket Screw

(308P151)

Motor Mounting

Screw (310P154)

Mounting

Bracket

VERTICAL CONTACT TOASTER VCT-20

14

P/N 1010719 Rev. C 12/99

A.J. Antunes & Co.

Rear Conveyor Cover Assy.

Weld Screws

Acorn Nuts

Spacers

Tensioner Assy.

Teflon Tape

Figure 18. Replacing Roller Tensioner Assy.

5. Place one drop of Loctite (Blue) into each thread-

ed hole in the gear reducer casting. Attach the

drive motor bracket to the gear reducer using the

original four 10-32 x 3/8" screws (310P154)

removed in step 3.

6. Attach the motor sprocket to the gear reducer as

shown in Figure 19.

NOTE: Be sure sprocket setscrew is positioned on the

flat of the gear reducer shaft. Maintain the 3/16"

dimension as shown in Figure 20. Apply Loctite (Blue)

to threads of setscrew and tighten securely.

7. Using the four new 8-32 x 5/16" stainless steel

SEMS truss head screws (P/N 308P151), attach

the drive motor bracket to the mounting bracket.

DO NOT tighten screws at this time.

8. Place the drive chain on the sprocket and push

down on motor. Allow 1/4" (0.6 mm) play at mid-

dle of drive chain, then tighten mounting screws

while holding motor. Check drive chain play after

tightening screws.

9. Re-connect motor wires, one at a time.

10. Re-install control cover.

Apply only 1 drop of Loctite (RED) to front of fan assy. after
assembly. Outer edge of fan blade hub to be flush with end of
motor shaft.

3/16"

(4.75 mm)

Apply Loctite (BLUE) on setscrew of sprocket and all other
mounting screws.

Figure 20. Replacing Drive Motor and Fan Blade

MAINTENANCE (continued)

Figure 19. Replacing Drive Motor and Fan Blade

POW

ER

TEMP

DOW

N

TEMP

UP

TEMP

SCALE

˚C

˚F

Fan Blade

Motor Sprocket

Drive Motor/Gear Reducer - Place 1 drop of
Loctite (Blue) into each threaded mounting
hole of reducer before installing.

Drive Motor
Bracket

Mounting
Bracket Screw
(308P151)

Motor Mounting
Screw (310P154)

Mounting
Bracket

Advertising