Icx-250 specifications – ADC ICX-250 User Manual

Page 12

Advertising
background image

Product Overview

Welcome 5

Issue 1, September 1998

ADCP-62-023

© 1998, ADC Telecommunications, Inc.

ICX-250 Specifications

Chassis
Specification

Height
Width
Depth
Weight

1.75 inches (with feet 2 inches)
17.25 inches
12 inches
Approximately 10 pounds

Installation

Desktop
Wall Mount
Rackmount

Power Supply

Ring Generator

AC
DC

120V .6A Max. 60Hz (104 - 140 VAC)
–48V, –24V, or +24V 1.8A Max. (22.5 - 57 VDC)
Integrated AC/DC converter and Ringing Generator

Nominal 50 VRMS
Frequency 20 +/–1 Hz
DC component: –30 volts nominal
Crest factor cf, where 1.2=<cf=<1.6
Ringing Capability: 40 Vrms across 1 REN at the end of a 400 ohms loop.

Environment

Operating Temperature
Storage Temperature
Relative Humidity

0

0

C to 40

0

C

–40

0

C to 66

0

C

5 to 85% Humidity, Non-Condensing

Regulatory
Compliance

FCC Regulatory #

FCC Part 15 Class A
UL 1950 and CSA C22.2 950
FCC Part 68 and Industry Canada CS-03

1H5USA-32637-DE-N

Product Numbers

240212
240224

12 FXS ports, 2 EIA530A/V.35 data ports
24 FXS ports, 2 EIA530A/V.35 data ports

T1 Interface

Physical
Frame Format
Line Code
CSU Line Build Out
(LBO)
DSX Line Length
Clocking
FDL

One RJ48
D4, ESF, TR-08
AMI, B8ZS
0 dB, –7.5 dB, –15.0 dB
0.6 dB at 0-266 ft., 1.8 dB at 266 - 533 ft., 3.0 dB at 533 - 655 ft.
Internal Stratum 4, Line
Per ANSI T1.403 and AT&T TR62411

FXS Interface

Physical
FXS Supervision Mode
FXS Signaling

TLP
Impedance
Ringing Voltage

One 50-pin Female Amphenol
FXS, FXS-DN, FXS-DN-Wink, TR-08
Loop Start, Ground Start, Loop Start w/ forward Disconnect, Ground
Start Immediate, Ground Start Automatic, Universal Voice Grade,
Universal Voice Grade Automatic, Single-Party
–3 dB/–9 dB on Rx, + 3 dB/+9 dB on Tx
600 Ohm
50 Vrms
On hook transmission for Caller ID support

Data Interface

Physical
Data Rate

Two (2) EIA530A/V.35 ports (DB25)
Nx56K, Nx64K (N = 1 to 24)

Diagnostics

Extensive power-up self test
LED Indicators
QRSS Test Pattern on T1
2047 Test Pattern on Data ports
Loopbacks for FXS, T1 and Data ports
CSU Loopback detection
Performance statistics over FDL
Bantam jacks for in-session T1 monitoring and line testing

DIP Switch
Settings

FXS, T1, Data port Loopbacks, CSU Loopback Detection, Clocking,
T1 Frame Format, T1 Line Code, T1 Line Build Out, FXS TLP, FXS
Supervision, FXS Signaling, Trunk Conditioning, Test Patterns, Data rate.

Advertising