This – ADC ICX-250 User Manual

Page 41

Advertising
background image

36 Configuring the ICX-250

External DIP Switches

ADCP-62-023

Issue 1, September 1998

© 1998, ADC Telecommunications, Inc.

Decimal / Binary Conversion Table for Data Port Configuration

The table shown below illustrates the binary equivalent of Timeslots 1-24.
Note: 1 = ON and 0 = OFF.

This

table is used for selecting the starting timeslots for each data port.

Bandwidth

Timeslot

Switch Setting

Bandwidth

Timeslot

Switch Setting

--

0

00000

832K

13

01101

64K

1

00001

896K

14

01110

128K

2

00010

960K

15

01111

192K

3

00011

1024K

16

10000

256K

4

00100

1088K

17

10001

320K

5

00101

1152K

18

10010

384K

6

00110

1216K

19

10011

448K

7

00111

1280K

20

10100

512K

8

01000

1344K

21

10101

576K

9

01001

1408K

22

10110

640K

10

01010

1472K

23

10111

704K

11

01011

1536K

24

11000

768K

12

01100

Starting T/S

6

7

8

9

1

off

off

off

off

3

off

off

off

on

5

off

off

on

off

7

off

off

on

on

9

off

on

off

off

11

off

on

off

on

13

off

on

on

off

15

off

on

on

on

19

on

off

off

on

21

on

off

on

off

23

on

off

on

on

Advertising