ADC ICX-250 User Manual

Page 27

Advertising
background image

22 Configuring the ICX-250

Switches

ADCP-62-023

Issue 1, September 1998

© 1998, ADC Telecommunications, Inc.

T1 INTERFACE:

T1 Interface
Frame Format
(see page 32)

S1
positions 1 and 2

Back

D4 (SF)
ESF
TR-08

Selects the T1 frame format and
data link format to be either D4
(SF), ESF, or TR-08. (No data link
with D4).

T1 Interface
Line Code
(see page 32)

S1
position 3

Back

AMI
B8ZS

Selects the line code on the T1
interface.

T1 Interface
T1 Clock
(see page 33)

S1
position 4

Back

Line
Internal

Line: Clock for the T1 interface
will be recovered from the line
(receive signal).
Internal: Clock for the T1 interface
will be taken from an on-board
1.544 MHz clock meeting the
Stratum 4 requirements.

T1 Interface
CSU Loop Code
Recognition
(see page 34)

S1
position 5

Back

Accept
Ignore

Accept: ICX-250 will respond to
network generated loop requests
that are received over the FDL.
Ignore: ICX-250 will ignore
network generated loop requests.

T1 Interface
Line Build Out
(see page 34)

S1
positions 6 and 7

Back

0 dB
–7.5 dB
–15.0 dB

Selects one of three line build
out options for short (–15.0 dB),
medium (–7.5 dB) and long (0 dB)
loops.

DATA PORTS:

Data Ports 1 and 2
Number of Timeslots
(see page 35)

S2 - dataport 2
positions 1, 2, 3, 4
and 5
S3 - dataport 1
positions 1, 2, 3, 4
and 5

Back

0
1, 2, 3, ....24

Selects the number of timeslots
that data from Data Port 1
and/or 2 will be mapped onto.

Data Ports 1 and 2
Starting Timeslot
(see page 37)

S2 - dataport 2
positions 6, 7, 8, 9
and 10
S3 - dataport 1
positions 6, 7, 8, 9
and 10

Back

0
1, 2, 3, ....24

Selects first T1 timeslot that data
from Data Port 1 and/or 2 will be
mapped.

Data Ports 1 and 2
Interface Type
(see page 38)

S2, S3
position 11

Back

EIA530A
V.35

EIA530A: Ports 1 and/or 2 use
the EIA530A standard.
V.35: Ports 1 and/or 2 use the V.35
standard.

Data Ports 1 and 2
Data Rate
(see page 39)

S2, S3
position 12

Back

64 Kbps
56 Kbps

64Kbps: Ports 1 or 2 receive
and transmit data at a multiple
of 64 Kbps.
56Kbps: Ports 1 or 2 receive
and transmit data at a multiple
of 56 Kbps.

The bold highlighted selection under “Options” is the Factory Setting.

Function

Switch

Switch

Location

Option

Description

Advertising