Fxs supervision - type, Single part service for slc-96 – ADC ICX-250 User Manual

Page 29

Advertising
background image

24 Configuring the ICX-250

Switches

ADCP-62-023

Issue 1, September 1998

© 1998, ADC Telecommunications, Inc.

FXS Supervision - Type

(DIP switches - internal)

Description: S6 and S7 positions 3, 4 and 5 determine the FXS type. Options are: Loop Start,
Single Party, Ground Start, Ground Start Automatic, Ground Start Immediate, Universal Voice
Grade, Universal Voice Grade Automatic and Loop Start Forward Disconnect.

Factory Setting: LOOP START

Loop Start: Tip and Ring closure used with traditional telephone stations and simple PBX lines.

Loop Start-Forward Disconnect: Provides disconnect when FXS is connected to voice messaging
system.

Ground Start: Used with two-way PBX lines.

Ground Start Automatic: Used with equipment requiring fast-response time to the central
office (CO).

Ground Start Immediate: Used with equipment requiring fast-response time to the station or PBX.

Single Party:

Single Part Service for SLC-96.

Universal Voice Grade: Toll quality voice for SLC-96.

Universal Voice Grade Automatic: Used with some non-bell switches.

1 2 3 4 5 6 7 8

ON DIP

S7

1 2 3 4 5 6 7 8

ON DIP

S6

1 2 3 4 5 6 7 8

ON DIP

S17

1 2 3 4 5 6 7 8

ON DIP

S18

1 2 3 4 5 6 7 8

ON DIP

S19

1 2 3 4 5 6 7 8

ON DIP

S14

1 2 3 4 5 6 7 8

ON DIP

S16

1 2 3 4 5 6 7 8

ON DIP

S15

S1

S2

S3

S4

S5

BACK

FRONT

S16

S15

S19

S18

S17

S14

S7

S6

see FXS Supervision Table