Data port 1 and 2 - number of timeslots, Iicx-250 - rear panel – ADC ICX-250 User Manual

Page 40

Advertising
background image

External DIP Switches

Configuring the ICX-250 35

Issue 1, September 1998

ADCP-62-023

© 1998, ADC Telecommunications, Inc.

Data Port 1 and 2 - Number of Timeslots

(DIP switch - back)

IICX-250 - Rear Panel

Switch numbers S1 through S5 are shown on the board within the unit.

Description: S2 positions 1, 2, 3, 4 and 5 (Data 2 - DIP switch) sets the port parameters for Data
Port 2. S3 positions 1, 2, 3, 4 and 5 (Data 1 -DIP switch) sets the port parameters for Data Port 1.
Both DIP switches are used for Network Data Bandwidth.

Factory Setting: All switches are set to zero (data ports inactive).

Number of Timeslots: Selects the number of consecutive timeslots that data from Data Port 1 and/
or 2 will be mapped onto. Please refer to Decimal/Binary Conversion Table (see page 36) for Data
Port Configuration to aid in selecting N. Drawing above indicates switch settings if timeslot N = 13.
Selected quantity of timeslots x 64K = Data Port Bandwidth.

Note

:

Binary numbers are used to select the number

of timeslots and starting timeslots.

120 VAC–.6A 60Hz

24/48 VDC

+ – G

T1

Rx

Tx

T1 Line

T1

Data 2

Data 2

Data 1

1

12 13

24

ON

DIP

1

0

1

2 3 4 5 6 7 8 9 10 11 12

Alm.

Data 1

FXS Loopback

FXS Loop Pairs

S5

S4

S3

S2

S1

11271-A

Data 1 / Data 2

Advertising