ADC ICX-250 User Manual

Page 38

Advertising
background image

External DIP Switches

Configuring the ICX-250 33

Issue 1, September 1998

ADCP-62-023

© 1998, ADC Telecommunications, Inc.

T1 Interface - T1 Clock

(DIP switch - back)

ICX-250 - Rear Panel

Switch numbers S1 through S5 are shown on the board within the unit.

Description: S1 position 4 is used to select the T1 clock source.

Factory Setting: LINE

Line: Clock for the T1 interface will be recovered from the line (receive signal).

Internal: Clock for the T1 interface will be taken from an on-board 1.544 MHz clock meeting the
Stratum 4 requirements.

Note

:

Failure of external clock causes unit to switch

to internal clock. When external clock is restored, the
unit will switch back to external clock source.

120 VAC–.6A 60Hz

24/48 VDC

+ – G

T1

Rx

Tx

T1 Line

T1

Data 2

Data 2

Data 1

1

12 13

24

ON

DIP

1 2 3 4 5 6 7

Alm.

Data 1

FXS Loopback

FXS Loop Pairs

S5

S4

S3

S2

S1

11268-A

T1

LINE

ON

DIP

1 2 3 4 5 6 7

T1

INTERNAL

Advertising