The ICX-250 Unit

System Basics 13

Issue 1, September 1998

ADCP-62-023

© 1998, ADC Telecommunications, Inc.

The ICX-250 Unit

The ICX-250 comes equipped with either 12 FXS (model 240212) or 24
FXS (model 240224) analog voice ports depending on which model you
purchase. Each unit is designed to allow easy accessibility to switches and
electrical connectors. The diagrams below illustrate the front and rear
layout of the unit. The diagram on the next page illustrates the internal
layout of the unit.

Note

:

The 12 FXS or 24 FXS models are not field

upgradeable.

ICX-250 - Front Panel

ICX-250 - Rear Panel

ICX-250

1 3 5 7 9 11 13 15 17 19 21 23

2 4 6 8 10 12 14 16 18 20 22 24

FXS Status Channel

Data Loop 2

Lcl. / Off / Net.

Data Loop 1

Lcl. / Off / Net.

T1 Loop

Net. / Off / Lcl.

1 / Off / 2

Off / QRSS

T1 Status

T1 Loop

Test Pattern

Test Pattern

T1 T

est

Self Check

11261-A

120 VAC–.6A 60Hz

24/48 VDC

+ – G

T1

Rx

Tx

T1 Line

T1

Data 2

Data 2

Data 1

1

12 13

24 Alm.

Data 1

FXS Loopback

FXS Loop Pairs

11264-A

25 PAIR AMPHENOL

CONNECTOR FOR 24

FXS TIP AND RING PAIRS

DIP SWITCHES TO SET

LOOPBACK FOR EACH

FXS CHANNEL

ALARM RELAY

FOR EXTERNAL

ALARM SYSTEM

TWO DB25 FEMALE
CONNECTORS FOR

DATA PORT 1 AND 2

SIGNALS

DIP SWITCHES USED FOR DATA
PORT 1 AND 2 CONFIGURATION

DIP SWITCHES

USED FOR T1

INTERFACE

CONFIGURATION

RJ48 CONNECTOR

FOR TRANSMIT AND

RECEIVE TIP AND

RING PAIRS

DUAL BANTAM

JACK

(MONITOR JACKS)

TERMINAL BLOCK FOR

DC POWER SUPPLY

EARTH GROUND

POWER INPUT FOR

120 VAC RECEPTACLE

Advertising