Cyclades PR1000 User Manual

Page 25

Advertising
background image

Cyclades-PR1000

25

Chapter 4 - Step-by-Step Instructions

Please read the entire example and follow the instructions before turning the router on. The router is
programmed to log the super user off after 10 minutes of inactivity. All data not explicitly saved to
memory is then lost. Collecting the data

while

configuring the router will likely cause delays and

frustration.

STEP ONE
The first step is to determine the parameters needed to configure the Ethernet interface (ETH0). The parameters
in the Network Protocol Menu (IP) are shown in Figure 4.2. Fill in the blanks for your application in the right-most
column. These parameters will be entered into the router later, after all parameters have been chosen. Each
parameter in this menu is explained in more detail in chapter 5 of the Installation Manual.

Menu CONFIG=>INTERFACE=>ETHERNET=>NETWORK PROTOCOL=>IP
Parameter

Example

Your Application

Active or Inactive

Active enables IP communication (IPX
and Transparent Bridge are not used in
this example).

Interface Numbered
/Unnumbered

Numbered

Primary IP Address

192.168.0.1

Subnet Mask

255.255.255.0

Secondary IP
Address

0.0.0.0 for none.

IP MTU

Use the preset value, 1500. This
determines whether or not a given IP
datagram is fragmented.

this table continued

FIGURE 4.2 ETHERNET NETWORK PROTOCOL MENU PARAMETERS