AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 10

Advertising
background image

Introduction

4

NetLinx Integrated Controllers

NI-2000 Specifications (Cont.)

Digital I/O (Port 9)

Four-channel binary I/O port for contact closure

• Each input is capable of voltage sensing. Input format is software

selectable.

• Interactive power sensing for IR ports

• Channel range = 1-4

• All inputs are assigned to respective IR/Serial ports for "automatic" power

control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).

• Contact closure between GND and an I/O port is detected as a PUSH

• When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as

a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE

• When used as an output - each I/O port acts as a switch to GND and is

rated at 200 mA @ 12 VDC

• One 6-pin 3.5 mm mini-Phoenix (female) connector provides I/O port

termination

IR/Serial (Ports 5-8)

Four IR/Serial control ports support high-frequency carriers up to

1.142 MHz

• Each output is capable of two electrical formats: IR or Serial

• Four IR/Serial data signals can be generated simultaneously.

• Channel range = 1-32,767

• Channels 1-128 (output): IR commands

• Channels 129-253: used as reference channels

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

commands)

• Channel 255 (feedback): Power status (when IO Link is set)

• One 8-pin 3.5 mm mini-Phoenix (female) connector provides IR/Serial port

termination

IR/Serial (Ports 5-8)

Four IR/Serial control ports support high-frequency carriers up to 1.142

MHz

• Each output is capable of two electrical formats: IR or Serial

• Four IR/Serial data signals can be generated simultaneously

• Channel range = 1-32,767

• Channels 1-128 (output): IR commands

• Channels 129-253: used as reference channels

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

commands)

• Channel 255 (feedback): Power status (when IO Link is set)

• One 8-pin 3.5 mm mini-Phoenix (female) connector provides IR/Serial port

termination

Program port

• Single RS-232 DB9 connector (male) can be connected to a DB9 port on a

computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.2 program.

Configuration DIP switch

• Use this DIP switch to set the communication parameters for the rear

RS232 Program port.

ID pushbutton

• Sets the NetLinx ID (D) assignment for the device.

• The D notation is used to explicitly represent a device number.

Ethernet port

• Single RJ-45 port for 10/100 Mbps communication. The Ethernet Port

automatically negotiates the connection speed (10 Mbps or 100 Mbps) and
whether to use half duplex or full duplex mode.

Advertising
This manual is related to the following products: