AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 19

Advertising
background image

Introduction

13

NetLinx Integrated Controllers

NI-4000 Specifications (Cont.)

Digital I/O (Port 17)

Eight-channel binary I/O port for contact closure

• Each input is capable of voltage sensing. Input format is software

selectable.

• Interactive power sensing for IR ports

• Channel range = 1-8

• All inputs are assigned to respective IR/Serial ports for "automatic" power

control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).

• Contact closure between GND and an I/O port is detected as a PUSH

• When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as

a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE

• When used as an output - each I/O port acts as a switch to GND and is

rated at 200 mA @ 12 VDC

• One 10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port

termination

IR/Serial (Ports 9-16)

Eight IR/Serial control ports support high-frequency carriers up to

1.142 MHz

• Each output is capable of two electrical formats: IR or Serial

• Eight IR/Serial data signals can be generated simultaneously.

• Channel range = 1-32,767

• Channels 1-128 (output): IR commands

• Channels 129-253: used as reference channels

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

commands)

• Channel 255 (feedback): Power status (when IO Link is set)

• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port

termination

Program port

• Single RS-232 DB9 connector (male) can be connected to a DB9 port on a

computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.2 program.

Configuration DIP switch

• Use this DIP switch to set the communication parameters for the rear

RS232 Program port.

ID pushbutton

• Sets the NetLinx ID (D) assignment for the device.

• The D notation is used to explicitly represent a device number.

Ethernet port

• Single RJ-45 port for 10/100 Mbps communication. The Ethernet Port

automatically negotiates the connection speed (10 Mbps or 100 Mbps) and
whether to use half duplex or full duplex mode.

Ethernet Link/Activity LED

• LEDs show communication activity, connections, speeds, and mode

information:

SPD-speed - Yellow LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.

L/A-link/activity - Green LED lights On when the Ethernet cables are
connected/terminated correctly and blinks when receiving Ethernet data
packets.

AXlink LED

• One green LED indicates the state of the AXlink connector port.

• Normal AXlink activity = 1 blink/second

• Abnormal AXLink activity = cycle of 3 consecutive blinks and then Off

AXlink port

• 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to

external control devices.

Power port

• 2-pin 3.5 mm mini-Phoenix (male) connector