AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 14

Advertising
background image

Introduction

8

NetLinx Integrated Controllers

NI-3000 Specifications (Cont.)

Rear Panel Components:

RS-232/422/485 (Ports 1 -7)

Seven RS-232/422/485 control ports using DB9 (male) connectors with

XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.

• Channel range = 1-255

• Channels 1-254 provide feedback

• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a

'CTSPSH' command was sent to the port

• Output data format for each port is selected via software

• Seven DB9 connectors provide RS-232/422/485 termination

ICSNet

Two RJ-45 connectors for ICSNet interface

ICSHub Out

Single RJ-45 connector provides data to another Hub connected to the

Controller

Relay (Port 8)

Eight-channel single-pole single-throw relay ports

• Each relay is independently controlled.

• Supports up to 8 independent external relay devices

• Channel range = 1-8

• Each relay can switch up to 24 VDC or 28 VAC @ 1 A

• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay

termination

Digital I/O (Port 17)

Eight-channel binary I/O port for contact closure

• Each input is capable of voltage sensing. Input format is software

selectable.

• Interactive power sensing for IR ports

• Channel range = 1-8

• All inputs are assigned to respective IR/Serial ports for "automatic" power

control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).

• Contact closure between GND and an I/O port is detected as a PUSH

• When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as

a PUSH and a high signal (3.5 - 5 VDC) as a RELEASE

• When used as an output - each I/O port acts as a switch to GND and is

rated at 200 mA @ 12 VDC

• One 10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port

termination

IR/Serial (Ports 9-16)

Eight IR/Serial control ports support high-frequency carriers up to

1.142 MHz

• Each output is capable of two electrical formats: IR or Serial

• Eight IR/Serial data signals can be generated simultaneously.

• Channel range = 1-32,767

• Channels 1-128 (output): IR commands

• Channels 129-253: used as reference channels

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

commands)

• Channel 255 (feedback): Power status (when IO Link is set)

• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port

termination