Ir/serial connections and wiring – AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 32

Advertising
background image

Connections and Wiring

26

NetLinx Integrated Controllers

IR/Serial Connections and Wiring

You can connect up to eight IR- or Serial-controllable devices to the IR/Serial connectors on the

rear of the NI-4000 and NI-3000 and up to four on the NI-2000 (FIG. 16). These connectors accept

an IR emitter (CC-NIRC) that mounts onto the device's IR window, or a mini-plug (CC-NSER) that

connects to the device's control jack. You can also connect a data 0 - 5 VDC device. These units

come with two CC-NIRC IR emitters (FG10-000-11).

The IR/Serial connector wiring specifications are listed in the following table.

I/O Port Wiring Specifications

NI-4000 and NI-3000

I/O Port Wiring Specifications NI-2000

Pin

Signal

Function

Pin

Signal

Function

1

GND

Signal GND

1

GND

Signal GND

2

I/O 1

Input/Output

2

I/O 1

Input/Output

3

I/O 2

Input/Output

3

I/O 2

Input/Output

4

I/O 3

Input/Output

4

I/O 3

Input/Output

5

I/O 4

Input/Output

5

12 VDC

PWR

6

I/O 5

Input/Output

7

I/O 6

Input/Output

8

I/O 7

Input/Output

9

I/O 8

Input/Output

10

12 VDC

PWR

FIG. 16 IR/SERIAL (male)

IR/Serial Connector Wiring Specifications

No.

NI-4000/3000 Port

NI-2000 Port

Signal

Function

1

9

5

GND (-)

Signal 1 (+)

2

10

6

GND (-)

Signal 2 (+)

3

11

7

GND (-)

Signal 3 (+)

4

12

8

GND (-)

Signal 4 (+)

5

13

N/A

GND (-)

Signal 5 (+)

6

14

N/A

GND (-)

Signal 6 (+)

7

15

N/A

GND (-)

Signal 7 (+)

8

16

N/A

GND (-)

Signal 8 (+)

IR / SERIAL (Ports 5-8)

IR / SERIAL (Ports 9-16)

8

7

6

4

5

3

2

1

4

2

3

1

NI-4000/NI-3000 IR/Serial connector

configuration (Port 9-16)

NI-2000 IR/Serial connector

configuration (Port 5-8)