Connections and Wiring

18

NetLinx Integrated Controllers

Using the Configuration DIP switch

1.

Disconnect the power supply from the 2-pin PWR (green) connector on the rear of the NetLinx

Integrated Controller.

2.

Set DIP switch positions according to the information listed in the Baud Rate Settings on the

Configuration DIP Switch and PRD Mode Settings tables.

3.

Reconnect the 12 VDC power supply to the 2-pin 3.5 mm mini-Phoenix PWR connector.

Modes and Front Panel LED Blink Patterns

The following table lists the modes and blink patterns for the front panel LEDs associated with

each mode. These patterns are not evident until after the unit is powered.

Wiring Guidelines

The Integrated Controllers require 12 VDC power from a NetLinx Power Supply to operate

properly (this supply is unit dependent). The Integrated Controller connects to the power supply via

a 2-pin 3.5 mm mini-Phoenix connector.

Think of the PRD Mode (On) equating to a PC’s SAFE Mode setting. This mode
allows a user to continue powering a unit, update the firmware, and download a new
program while circumventing any problems with a currently downloaded program.
Power must be cycled to the unit after activating/deactivating this mode on the
Program Port DIP switch #1.

Modes and LED Blink Patterns

LEDs and Blink Patterns

Mode

Description

STATUS

(green)

OUTPUT

(red)

INPUT

(yellow)

OS Start

Starting the operating system (OS).

On

On

On

Boot

On-board Master is booting.

On

Off

On

Contacting DHCP
server

On-board Master is contacting a DHCP
server for IP configuration information.

On

Off

Fast Blink

Unknown DHCP
server

On-board Master could not find the
DHCP server.

Fast Blink

Off

Off

Downloading Boot
firmware

Downloading Boot firmware to the
Master’s on-board flash memory.

Do not cycle power during this process!

Fast Blink

Fast Blink Fast Blink

No program running

There is no program loaded, or the
program is disabled.

On

Normal

Normal

Normal

On-board Master is functioning normally.

1 blink per second

Indicates

activity

Indicates

activity

This unit should only have one source of incoming power. Using more than one
source of power to the Controller can result in damage to the internal components
and a possible burn out.
Apply power to the unit only after installation is complete.