Connections and Wiring

24

NetLinx Integrated Controllers

Ethernet LEDs

Ethernet ports used by the Integrated Controllers

Relay Connections and Wiring

You can connect up to 8 independent external relay devices on both the NI-4000 and NI-3000 units

(4 on the NI-2000) to the Relay connectors on the Integrated Controller (Port 7).

Connectors labeled A are for common; B are for output.

Each relay is isolated and normally open.

FIG. 12 RJ-45 wiring diagram

FIG. 13 Layout of Ethernet LEDs

Ethernet Ports Used by the NetLinx Integrated Controllers

Port type

Description

Standard Port #

ICSP

Peer-to-peer protocol used for both Master-to-Master and Master-to-device
communications.

For maximum flexibility, the on-board Master can be configured to utilize a
different port than 1319, or disable ICSP over Ethernet completely from
either Telnet or the Program Port located on the rear of the Controller itself.

1319 (UDP/TCP)

Telnet

The NetLinx Telnet server provides a mechanism to configure and
diagnose a NetLinx system.

For maximum flexibility, the on-board Master can be configured to utilize a
different port than 23, or disable Telnet completely from either Telnet or the
Program Port located on the rear of the Controller itself. Once disabled, the
only way to enable Telnet again is from the Controller’s program port.

23 (TCP)

HTTP

The on-board Master has a built-in web server that complies with the
HTTP 1.0 specification and supports all of the required features of
HTTP v1.1.

80 (TCP)

HTTPS

The Master has a built-in SSL protected web server.

443 (TCP)

FTP

The on-board Master has a built-in FTP server that conforms to RFC959.

21/20 (TCP)

Internet Inside The Internet Inside feature the on-board Master uses, by default, is port

10500 for the XML based communication protocol. This port is connected
to the client web browser’s JVM when Internet Inside control pages are
retrieved from the on-board Master’s web server.

For maximum flexibility, the on-board Master can be configured to utilize a
different port than 10500 or to disable Internet Inside completely.

10500 (TCP)

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

RJ-45
plug

RJ-45

plug

10/100

ETHERNET

SPD - Speed LED

connection speed is 100 Mbps
and turns Off when speed is

lights (yellow) when the

L/A - Link/Activity LED

lights (green) when the

Ethernet cables are

connected and terminated

10 Mbps.

correctly.