5-53

XTRAEDIT CONFIGURATION

Preferences menu. If inches, the user can enter a value between -1.000

and 1.000. In 1/300 inches, the user can enter an integer value between

-300 and 300. In 1/60 inches, the user can enter an integer value between

-60 and 60. The default value is -75 (300ths inch).

Left Offset
Left Offset specifies the amount of shift if Offset is selected (or active

because of the Auto Offset algorithm) under Size Correction. Negative

values move printed output left; positive values move printed output

right. The value can be entered in inches, 1/300 inches or 1/60 inches,

depending upon the setting of Measurement Setting for Entries under the

Preferences menu. If inches, the user can enter a value between -1.000

and 1.000. In 1/300 inches, the user can enter an integer value between

-300 and 300. In 1/60 inches, the user can enter an integer value between

-60 and 60. The default value is -75 (300ths inch).

Minimum Top Coordinate
The Minimum Top Coordinate setting is used if Auto Offset has been

selected under Size Correction in the Printer Setup menu. The XLI uses

this value to determine if the origin of the first character is in the

printable area of the page. The value entered by the user should normally

be 1/4 inch, since this is the area at the top of the page that cannot be

addressed by PCL5 printers. The default is 75 (300th inch). This value

may need to be increased if the origin of the character is within the

printable area, but the height of the character is such that the character is

clipped when printed.
The value can be entered in inches, 1/300 inches or 1/60 inches,

depending upon the setting of Measurement Setting for Entries under the

Preferences menu. If inches, the user can enter a value between 0.000

and 14.000. In 1/300 inches, the user can enter an integer value between

0 and 4200. In 1/60 inches, the user can enter an integer value between 0

and 840.

Minimum Left Coordinate
The Minimum Left Coordinate setting is used if Auto Offset has been

selected under Size Correction in the Printer Setup menu. The XLI uses

this value to determine if the origin of the first character is in the

printable area of the page. The value entered by the user should normally

be 1/4 inch, since this is the area on the left edge of the page that cannot

be addressed by PCL5 printers.