Programming the Agilent 603xA Power Supplies Using Basic

122

Service Request

Service request provides the programmer with the means for interrupting the controller when a fault condition occurs.
Service is requested when the FAU bit in the serial poll register, which is the logical OR of all bits in the fault register,
becomes true with SRQ enabled.

The mask register is used to specify conditions which can cause an interrupt. The fault register can be read to determine
which condition caused an interrupt.

The following commands enable and disable the service request function:

OUTPUT @PS;"SRQ ON"

OUTPUT @PS;~SRQ OFF"

EXAMPLE 7: Enable an interrupt upon a transition to overrange mode. This non-functional example is intended to
show the syntax necessary for setting up an interrupt. A similar sequence of commands can be used to define an
interrupt on any status condition(s) so as to get the controller’s attention as quickly as possible upon transition to a
fault condition.

10

ASSIGN @Ps TO 705

20

COM /Ps/ @Ps

30

OUTPUT @Ps; “CLR;UNMASK OR;SRQ ON”

40

ON INTR 7.1 CALL Err_trap

50

ENABLE INTR 7:2

60

!

70

!

80

! DO PROGRAM

90

!

100

!

110

END

120

!

130

!

140

SUB Err_trap

150

OFF INTR"

160

COM /Ps/ @Ps

170

OUTPUT @Ps;FAULT?”

180

Spoll_resp=SPOLL (@Ps)

190

!

200

!

210

! PROCESS INTERRUPT

220

!

230

!

240

SUBEND

Explanation:

10:

Assign I/O path name to power supply

20:

Declare common block for I/O path name

30:

Enable service request on transition to 'OR' mode

40:

Define interrupt at interface 7, (GP-IB) priority 1

50:

Enable interrupt at interface 7 on SRQ

140:

Define error handling routine

150:

Disable interrupt capability while processing

160:

Bring in common block for I/O path name

170:

Read fault register to clear FAU bit in serial poll register

180:

Conduct serial poll to clear RQS bit