Programming the Agilent 603xA Power Supplies Using Basic

127

130

OUTPUT @Ps:"VSET 3.ISET 6.7.STO3"

140

OUTPUT @Ps:"VSET 4,ISET 5.STO4"

150

OUTPUT @Ps:"VSET 5,ISET 4,STO5;CLR;OUT ON"

160

!

170

! NOTE: CLR COMMAND DOES NOT CLEAR THE STATE REGISTERS. THE LAST

180

! FOR STATES HAVE FOLDBACK ENABLED.

190

!

200

!

210

! LOOP THROUGH THE STATES 10 TIMES

220

!

230

FOR Count=1 T0 10

240

FOR State=l T0 5

250

OUTPUT @Ps; "RCL";State

260

WAIT 2

270

NEXT State

280

NEXT Count

290

END

Explanation:

30:

Assign I/O path name to power supply

40:

Initialize power supply, inhibit output

110-150:

Store 5 states. Last 4 have foldback enabled. Line 150 reinitializes power supply after storing fifth state.

230-280:

Loop through the sequence of five states ten times