59 lau_control_dinconfig (0x0206), Digital input configuration, Lau_control_dinconfig (0x0206) – Beijer Electronics SCOM Protocol EN User Manual

Page 104

Advertising
background image

Command Reference

104

Beijer Electronics, MAEN975

6.59 LAU_CONTROL_DINCONFIG (0x0206)

Digital Input Configuration

This command configures the digital input port. The setting is temporary, and does
not change the startup digital input port configuration.

Supported since Firmware Version
MT230 Nautic Monitor: 1.0

Command Stream

0

1

2

3

4

5

6

7...9

10

0x07

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x02

0x06

Param ICHKD

Param

Value:

0x00: Command “No operation”
0x01: Command “Set brightness”
0x02: Command “Special functions 1”
0x03: Command “Special functions 2”

Type:

Byte

Length:

1

Description: Command to be assigned to the digital I/O port.

The commands are specified as follows:
No operation
No function assigned to the digital input pins.
Set brightness
Input bits 0…2:

Eight predefined backlight level values.
These values can be configured.

Special functions 1
Input bits 0…1:

Route the value of input pins 0 and 1 to
the output pins 0 and 1.

Input bit 2:

1: Enable analog input to backlight level

control routing.

0: Disable analog input to backlight level

control routing.

Special functions 2
Input bit 0:

1: Enable ECDIS mode.
0: Disable ECDIS mode.

Input bit 1:

1: Enable POT mode.
0: Disable POT mode.

Input bit 2:

1: Disable OSD (video controller) keys.
0: Enable OSD (video controller) keys.