63 lau_status_potmode (0x0304), Current pot mode, Lau_status_potmode (0x0304) – Beijer Electronics SCOM Protocol EN User Manual

Page 110

Advertising
background image

Command Reference

110

Beijer Electronics, MAEN975

6.63 LAU_STATUS_POTMODE (0x0304)

Current POT Mode

Returns the current local backlight level control state. The local backlight level con-
trol mode can be changed by the standard SCOM command “POT” or digital input.

Supported since Firmware Version
MT230 Nautic Monitor: 1.0

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Example
Check whether local backlight level control is currently enabled for the monitor at
address 0.7 (group 0, address 7):

According to the data returned by the monitor at address 0.7 (group 0, address 7),
local backlight level control is currently enabled:

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x03

0x04

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Local backlight level control enabled
0x01: Local backlight level control disabled

Type:

Byte

Length:

1

Description: Current local backlight level control mode

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4C

0x41

0x55

0x02

0x0D

0x03

0x04

0xF8

0

1

2

3

4

5

6

7

8

0x06

0x07

0x4C

0x41

0x55

0x01

0x0F

0x00

0xFF

Advertising