7 mcc_contrast (0x82), Contrast, Mcc_contrast (0x82) – Beijer Electronics SCOM Protocol EN User Manual

Page 29

Advertising
background image

Command Reference

Beijer Electronics, MAEN975

29

6.7 MCC_CONTRAST (0x82)

Contrast

Adjusts or queries the contrast value of the video controller.

Supported since Firmware Version
MT230 Nautic Monitor: 1.0

Command Stream

0

1

2

3

4

5

6

7...7+[LEN]-1

7+[LEN]

0x07

ADR

0x4D

0x43

0x43

LEN

ICHKH 0x82 Ext

Ret

ICHKD

Ext:

Value:

A” or “a” (0x41 or 0x61)

Type:

ASCII character

Length:

1

Description: Command extension.

This character must be always sent as part of the sub-
command.

Param: ABSOLUTE

Value:

“00”: low … “FF”: high

Type:

Two-digit ASCII-encoded hexadecimal number

Length:

2

Description: New contrast value

Param: INC

Value:

“+” (0x2B)

Type:

ASCII character

Length:

1

Description: Increment the current contrast value

Param: DEC

Value:

“-” (0x2D)

Type:

ASCII character

Length:

1

Description: Decrement the current contrast value

Param: RESET

Value:

“R” or “r” (0x52 or 0x72)

Type:

ASCII character

Length:

1

Description: Reset the contrast to an internally predefined value

Param: QUERY

Value:

?” (0x3F)

Type:

ASCII character

Length:

1

Description: Query the current contrast value

Advertising