6.47 LAU_CONFIG_GETANALOGTOBRT

(0x011F)

Analog to Brightness Routing Mode

Some Beijer Electronics Nautic Monitor models are equipped with an expansion
port, where an analog potentiometer or a variable voltage can be connected, to con-
trol the backlight level of the monitor. This command returns the configuration of
the analog input port usage. If the analog port control is enabled, the backlight level
cannot be changed using the front panel keys, digital input or SCOM commands.

Supported since Firmware Version
MT230 Nautic Monitor: 1.0

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Example
Check whether the monitor at address 0.7 (group 0, address 7) is configured to use
the analog input for setting the backlight level:

According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor does not use analog input for backlight level control:

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x01

0x1F

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Routing from analog input to backlight level control disabled
0x01: Routing from analog input to backlight level control enabled

Type:

Byte

Length:

1

Description: Configuration of the analog input port usage

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4C

0x41

0x55

0x02

0x0D

0x01

0x1F

0xDF

0

1

2

3

4

5

6

7

8

0x06

0x07

0x4C

0x41

0x55

0x01

0x0F

0x00

0xFF