46 lau_config_getaddresslist (0x011e), Remote control address list, Lau_config_getaddresslist (0x011e) – Beijer Electronics SCOM Protocol EN User Manual

Page 82

Advertising
background image

Command Reference

82

Beijer Electronics, MAEN975

6.46 LAU_CONFIG_GETADDRESSLIST

(0x011E)

Remote Control Address List

If a Beijer Electronics Nautic Monitor is configured as remote controller, this com-
mand returns the addresses of monitors which should be controlled remotely. The
address list is returned as a bit field with 16 bits, enabling a total number of 16 mon-
itors to be controlled remotely. A Beijer Electronics Nautic Monitor always addresses
the monitors within its own group, starting with the lowest address. The group bits
are added automatically to the address field, before the command is sent.

Supported since Firmware Version
MT230 Nautic Monitor: 1.0

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
10

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x01

0x1E

ICHKD

0

1

2

3

4

5

6

7...8

8

0x06

ADR

0x4C

0x41

0x55

0x02

ICHKH

Ret

ICHKD

Ret

Value:

0...65535

Type:

Unsigned short

Length:

2

Description: Bit field containing the address list, where the first byte is

LSB. Each bit corresponds to one monitor address. Bit 0
specifies a monitor at address 0 and bit 15 a monitor at
address 15. If a bit is set (1), the corresponding monitor will
be controlled remotely.