Command Reference

Beijer Electronics, MAEN975

31

Example 3
Decrement the current contrast level of monitor at address 0.7 (group 0, address 7):

Monitor at address 0.7 (group 0, address 7) has returned the new contrast level 196
(0xC4):

Example 4
Reset the contrast level of monitor at address 0.7 (group 0, address 7):

Monitor at address 0.7 (group 0, address 7) has returned the default contrast level
128 (0x80):

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4D

0x43

0x43

0x03

0x1B

0x82

0x41

0x2D

0x0F

0

1

2

3

4

5

6

7...11

12

0x06 0x07 0x4D 0x43 0x43 0x05 0x1A 0x82 0x41 0x2D 0x43 0x34 0x98

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4D

0x43

0x43

0x03

0x1B

0x82

0x41

0x52

0xEA

0

1

2

3

4

5

6

7...11

12

0x06

0x07 0x4D 0x43 0x43 0x05 0x1A 0x82 0x41 0x52 0x38 0x30 0x82