6.15 ETC

Elapsed Time Counter

Queries the total operation time in hours. Internally, each monitor is equipped with
a software counter, which counts the full number of operation hours. The counter
value is limited to 298261, which is equivalent to approximately 34 years of opera-
tion time. After this time, each monitor returns always the maximum value. The
counter is incremented only, if the monitor was powered on one full hour without
interruption. If the monitor is powered off prior one full hour, the counter will re-
main at its last value.

Supported since Firmware Version
MT230 Nautic Monitor: 1.2-C118

Command Stream

(This command has no data)

Response Message (Acknowledge)

Response Message (Negative Acknowledge)

(No data is returned, in case of a negative acknowledge)

Maximum Lr for this Command
11

0

1

2

3

4

5

6

0x07

ADR

0x45

0x54

0x43

0x00

ICHKH

0

1

2

3

4

5

6

7...9

10

0x06

ADR

0x45

0x54

0x43

0x03

ICHKH Hours

ICHKD

Hours

Value:

0 … 298261

Type:

Byte Array

Length:

3

Description: Number of hours. The most significant byte is transmitted first

0

1

2

3

4

5

6

0x15

ADR

0x45

0x54

0x43

0x00

ICHKH

Advertising