Hydraulic requirements – Hawk Industries Hawkjaw Sr. Manual 100K-2GSR Serial Numbers 121 to 140 User Manual

Page 12

Advertising
background image

1. Pressure compensated pump set to

pressure compensate at 2500 psi.

2. Minimum volume of 20 gpm. 35 gpm for

top performance.

3. 1" minimum Pressure line. 1 1/4"

Pressure line if the power unit is located

more than 100' apart from the HawkJaw.

The hose working pressure must be 3000

psi or greater.

4. 1 1/4" minimum Tank line. 500 psi

minimum hose working pressure.

5. Hawk approved quick disconnects [Male:

Part # 061-H52 (MQD). Female: Part

# 061-H53 (FQD)]. Initial quick disconnects

supplied with the HawkJaw.

6. Hydraulic power unit located in a clean,

dry, ventilated area.

7. Enough slack in the lines for the HawkJaw

to move from its rest position to the drill

pipe connection to the mousehole

connection.

WARNING

The HawkJaw is a closed center system which must

have a pressure compensated volume controlled

power unit. If the only available hydraulic power

unit is constant volume, then the optional hydrau-

lic converter kit (Part # 061-J80) is required. Run-

ning the HawkJaw with a constant volume hydraulic

power unit may result in bodily injury and will cause

damage to the HawkJaw and to the hydraulic

power unit.

WARNING

The HawkJaw must receive clean hydraulic fluid.

Running the HawkJaw without a Hawk approved

filter (Part # 061-H25) and installed filter element

(Part # 061-H25A) voids the warranty and severely

shortens component life.

Installation 11

FQD Tank MQD Pressure

Hydraulic Requirements

Hydraulic Requirements

Advertising