Problem

Spinner begins to spin before the spinner

doors close on the drill pipe tube. (Cont.)

Spinner moves forward and the doors close

on the pipe, but the spinner does not spin.

Spinner retracts from the pipe and forces the

HawkJaw back away from the pipe.

Spinner chain slips on the drill pipe tube.

Spinner chain wears out prematurely.

Drill pipe does not rotate down to the

shoulder, or Spinner performance and speed

not up to par.

Remedy

Spinner motor sequence valve is located at Port

MSEQ on the main hydraulic block. See

Maintenance & Repair, Drawings.

Use an allen wrench to rotate the Spinner motor

sequence valve adjustment counter-clockwise until

the doors close and the spinner begins to spin. While

holding the sequence valve adjustment steady with

an allen wrench, lock in the adjustment by

tightening the differential valve lock nut. The

Spinner motor sequence valve is located at Port

MSEQ on the main hydraulic block. See

Maintenance & Repair, Drawings.

Use an allen wrench to rotate the Spinner retract

needle valve adjustment counter-clockwise until

spinner gradually opens as the spinner backs off the

pipe. While holding the needle valve adjustment

steady with an allen wrench, lock in the adjustment

by tightening the valve lock nut. The Spinner retract

needle valve is located at Port V9 on the Spinner

hydraulic block. See Drawings.

The spinner is adjusted too large for the drill pipe

tube. Adjust the spinner to the correct pipe size.

See Operation.

The spinner chain is worn out. Replace the spinner

chain. See Maintenance & Repair.

Lubricate the spinner chain. See Maintenance &

Repair.

Running the spinner with worn Drive rollers

severely shortens chain life. If the Drive Roller

Groove is no longer visible, replace the Drive

rollers. See Maintenance & Repair. Inspect the

chain. Replace the chain if the links are worn flat.

See Maintenance & Repair.

The spinner push cylinder is not stroke out far

enough to contact drill pipe with correct allignment.

See Adjusting Spinner.